4.2. Siemens ROLM PBX
The ROLM product family includes three generations of ROLM and related
PBXs:
PBXs:
1. The original ROLM
2. IBM ROLM 9751 series
3. Siemens Hicom 300 with the appropriate interface cards
The Dialogic
®
PBX Integration Board emulating the ROLM 400 telephone
can be used with these switches. The ROLM PBXs use digital signaling to
control their station sets and digitized voice.
control their station sets and digitized voice.
The Dialogic
®
PBX Integration Board has either four or eight channels that
can be connected directly to a station module in a Siemens ROLM PBX. The
PBX switch has many standard features that are supported by the PBX
Integration Board, such as:
PBX switch has many standard features that are supported by the PBX
Integration Board, such as:
• direct inward dialing (DID)
• speed dialing
• hunt groups
• message waiting indication
• user programmable feature keys
• called/calling number identification
• call forwarding
4.2.1. Siemens ROLM Programming Requirements
There are specific switch programming requirements that apply if using a
Dialogic
Dialogic
®
PBX Integration Board with a Siemens ROLM PBX. Pay attention
to set these features exactly (and assigned to the right keys) so that the PBX
Integration Board and the Dialogic
Integration Board and the Dialogic
®
Unified API can function correctly.
• All PBX Integration Board ports on a ROLM system must be
programmed as ROLMphone 400 telephones.
• LINE must be programmed on Feature Key 09, and the ROLMphone
must be programmed to select this line when going off-hook.