Microswitch faulty / out of adjustment 
Remove the right hand side panel to allow  
access  to  the  microswitch.   With  the  
thermostat  switched  on  and  door  closed, 
check voltage to terminal com of microswitch.  
If no voltage check wiring to thermostat. 
If  voltage  correct  then  check  voltage  at  
terminal  n.c.  If no  voltage  then  manually  
activate microswitch by bending the activator 
arm.  If microswitch cannot be activated then 
it is faulty - replace.   If the microswitch can be 
manually activated then it should be adjusted. 
6.1.4 OVEN LIGHTS NOT ILLUMINATING 
Light switch faulty 
Check voltage to the left hand terminal of the 
switch.  If there is no voltage, then check    
wiring. 
With switch depressed, check voltage at right 
hand terminal.  If there is no voltage, then  
replace the switch. 
If voltage is correct, then check wiring to light. 
NOTE:  Alternately, perform a continuity test 
across the terminals with the light 
switch depressed. 
6.1.5 NO WATER INJECTION / STEAM 
Steam switch faulty 
Check voltage to the left hand terminal of the 
switch.  If there is no voltage, then check    
wiring. 
With switch depressed, check voltage at right 
hand terminal.  If there is no voltage, then  
replace the switch. 
If voltage is correct, then check wiring to the 
solenoid. 
NOTE:  Alternately, perform a continuity test 
across the terminals with the steam switch  
depressed. 
 
Figure 6.1.1 
Microswitch 
com 
n.c. 
6.1.6  CONTINUOUS WATER OUT OF 
OVEN WATER NOZZLE 
Water solenoid electrical fault 
With   control   panel   steam   switch   not            
depressed, check for power supply across  
solenoid coil.  If there is power to the coil, then 
check wiring and steam switch (refer 6.1.7). 
6.1.7  60 MINUTE TIMER NO TIME UP 
BUZZER 
Buzzer faulty 
With timer in ‘zero’ position, check the buzzer 
at side of control panel (inside) for voltage 
across terminals.  If voltage is correct then 
buzzer is faulty—replace. 
If there is no voltage, then check wiring.. 
 
Timer not switching on buzzer 
With timer in zero position, check voltage to 
top  connection  (terminal  one)  and  bottom  
connection (terminal two) of timer.  If there is 
no voltage at terminal one then check wiring. 
If no voltage at terminal two then timer is 
faulty—replace. 
NOTE:   Timer   will   continue   to   run                 
approximately  three  minutes  below  zero.  
Buzzer and time up indicator will continue until 
the timer is manually switched off (to vertical 
position). 
Fault with water valve 
Check voltage supply across the water valve 
solenoid coil with the steam switch depressed.  
If there is no power supply then check the 
control panel steam switch.   
If   power   supply   to   the   coil   is   correct,           
disconnect   wiring   to   coil   and   check   the        
resistance of the coil windings. 
Correct coil resistance:  2500 ohms 
NOTE:  If open circuit / high resistance, then 
the coil is faulty—replace. 
If coil resistance is correct, rewire and listen 
for an audible solenoid click when the steam 
switch is depressed. 
If solenoid can be heard functioning, and oven 
water  nozzle  is  not  blocked,  then  remove   
water  solenoid  and  fittings  and  check  for 
blockages.