Konica Network Interface Card INSTRUCTION MANUAL  2-11
Chapter 2  Setting Up the Network Interface Card
Enable NetWare
When this box is checked, Novell NetWare (IPX/SPX) is enabled as a protocol for print servers. For
print servers on which NetWare is not a primary protocol, be sure to uncheck this box to disable
NetWare. This box is unchecked in the default setting.
Print Server Name
Each Novell print server has its own name, as assigned. For the print server (network interface card),
a default name, KON_(serial number), is used. The serial number is shown in the Status Page as well
as on the label affixed to the back of the network interface card.
If you want to use a name other than the default name or if you want to change the currently assigned
name, you can type a new print server name into this field. 63 characters can be typed in half size. It is
imperative that the name be identically changed on PCONSOLE as well. Otherwise, your newly en-
tered name will be ineffective.
Print Server Password
The network administrator assigns passwords to Novell print servers. When passwords are assigned
with PCONSOLE or NWADMIN, those passwords should be set up on the print servers. In Bindery
mode, only upper case passwords can be used.
When typing a password into this field, it must be identical to the password assigned through
PCONSOLE or NWADMIN. The typed password is stored in print server setup memory. For assigning
passwords using PCONSOLE, refer to the Novell manual.
When setting up a print server password, type a password into the [Print Server Password] field, and
then again type the same password into the [Password Retype] field for confirmation. This password is
common to all file servers assigned to the print server.
Clicking the [Accept Settings] button will have no effect unless you type one and the same password
both in the [Print Server Password] and [Password Retype] fields.
Password Retype
Type a password here, for confirmation.
Preferred Bindery File Server
Type a primary file server name in this field to designate a particular file server for your print server to
access. This feature allows you to access a desired file server and avoid accessing an undesired file
server as when the system is set to search for a file server.
Preferred NDS Context
If you are using Novell NetWare 4.x Directory Services, type a preferred NDS context here. The pre-
ferred NDS context needs to be a complete context name. Do not type a period (“.”) in the front of the
context pass. You do not need to type a container name (print server name) since it is in the name field
above. Here are examples of contexts with type:
Complete Context
o=standard.ou=organization_1