Lathem DDC2 사용자 설명서

다운로드
페이지 63
 
Digital Display Wall Clock Guide 
Page 8 
 
When used as a RS485 clock, the master clock will send a signal to the wall clock every minute. The 9-
Volt alkaline battery (not included) is optional in these types of installations. 
Battery Installation - DDC2 / DDC4 Series 
DDC2 
Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and 
circuit board assembly out of the case. Place the lens aside and carefully flip the circuit board assembly 
over and lay it face down on a clean, smooth work surface. Locate the Battery Cradle on the upper right 
corner of the circuit board assembly. (See figure 2, page 9) Slide the battery into the cradle making sure the 
Positive and Negative connections of the battery and cradle match. Snap the battery onto the connections 
located inside the battery cradle. Slide the lens and circuit board assembly back into the case, replace the 
end cap and secure with the four phillips head screws. 
DDC4 
Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel 
assembly out of the case. Carefully flip the front panel assembly over and lay it face down on a clean, 
smooth work surface. Locate the Battery Cradle on the upper right corner of the circuit board assembly. 
(See figure 2, page 9) Slide the battery into the cradle making sure the Positive and Negative connections of 
the battery and cradle match. Snap the battery onto the connections located inside the battery cradle. Slide 
the front panel display back into the case, replace the end cap and secure with the two phillips head screws. 
Power Cord Installation - DDC2/4-RS 
Note: This section refers only to the 115VAC models. Applying power other than 24VAC to models DDC2-
RS-24 or DDC4-RS-24 WILL CAUSE DAMAGE and void the warranty. See Appendix B for proper wiring 
of these models. 
DDC2-RS 
Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and 
circuit board assembly out of the case. Place the lens aside and carefully flip the circuit board assembly 
over and lay it face down on a clean, smooth work surface. Remove one of the vent caps from the case of 
the wall clock and route the power cord through it to the back of the circuit board assembly. (If the power 
cord will be routed through the back-of-the-clock conduit access, route the cord through the gang box and 
conduit access hole to the back of the circuit board assembly). Strip away 1/2" of the protective shield from 
each wire of the power cord. Locate the two black wires leading from J1 (see figure 2, page 9) and attach 
the AC In line of the cord to one and the AC Return line to the other. (normally black is AC In and white is