Lathem DDC2 사용자 설명서

다운로드
페이지 63
Page 13 
Digital Display Wall Clock Guide 
 
DDC2 
Note: If mounting near a ceiling, make sure the top of the single gang box is at least 2 1/4" away from the 
ceiling. 
Note: Make sure you have at least 10 1/2" of side clearance on one side in order to remove the lens and 
circuit board assembly. 
 
» 
Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens 
and circuit board assembly out of the case and set aside. 
» 
Remove the desired vent cap that any required wiring will route through. (If the wiring will be 
installed through the back-of-the-clock conduit access, route the fly leads of the clock's Cable 
Harness Assembly from the interior of the clock through the hole in the Clock's rear plate. Use 
wire nuts or crimp connectors to join these leads with the power and synch signal cable in the 
gang box behind the clock to eliminate possible snagging when the circuit board assembly is 
removed or replaced. If RS-485 signaling is used, attach the signal pair to the mini Terminal Block 
Plug and pass the cable from behind the clock, through the hole into the clock's interior). 
» 
Line the two holes in the case up to the single gang box and insert proper screws for the single 
gang box and tighten securely. 
» 
Route the 6-position plug (and optional RS485 cable) to the circuit board assembly and attach. 
» 
Slide the lens and circuit board assembly back into the case, replace the end cap and secure with 
the four phillips head screws. 
DDC4 
Note: If mounting near a ceiling, make sure the top of the single gang box is at least 2 1/4" away from the 
ceiling. 
Note: Make sure you have at least 16" of side clearance on one side in order to remove the front panel. 
 
» 
Remove the two phillips head screws from the left or the right end cap and remove. Slide the front 
panel assembly out of the case and set aside. 
» 
Remove the desired vent cap that any required wiring will route through. (If the wiring will be 
installed through the back-of-the-clock conduit access, route the fly leads of the clock's Cable 
Harness Assembly from the interior of the clock through the hole in the Clock's rear plate. Use 
wire nuts or crimp connectors to join these leads with the power and synch signal cable in the 
gang box behind the clock to eliminate possible snagging when the circuit board assembly is 
removed or replaced. If RS-485 signaling is used, attach the signal pair to the mini Terminal Block 
Plug and pass the cable from behind the clock, through the hole into the clock's interior). 
» 
Line the two holes in the case up to the single gang box and insert proper screws for the single 
gang box and tighten securely. 
» 
Route the 6-position plug (and optional RS485 cable) to the circuit board assembly and attach.