Advanced Features  
Add Multiple Scene Responders 
(formerly “Multi-Linking Mode”) 
1)  Tap Scene Controller button on KeypadLinc 
2)  Press and hold KeypadLinc’s Set Button until it beeps  
 
KeypadLinc’s Scene button LED will blink 
 
All illuminated LEDs on KeypadLinc will brighten to 100% 
3)  Tap KeypadLinc’s Set Button 
 
KeypadLinc’s Scene button LED will continue blinking 
4)  For each Responder you are adding 
a.  Adjust Responder to desired Scene state (for KeypadLincs you must tap the button at 
least once – until in desired state) 
b.  Press and hold Responder’s Set button until it beeps (or LED flashes)  
KeypadLinc will (Beep) 
5)  After all Responders have been added, tap KeypadLinc’s Set Button 
 
KeypadLinc’s Scene button LED will stop blinking 
 
 
 
KeypadLinc’s LEDs will return to normal brightness 
6)  Test Scene by tapping Scene button a couple of times  
 
All the Responders added above will respond  
Remove Multiple Scene Responders 
(formerly “Multi-Unlinking Mode”) 
1)  Tap Scene Controller button on KeypadLinc 
2)  Press and hold KeypadLinc’s Set Button until it beeps  
 
KeypadLinc’s Scene button LED will blink 
 
All illuminated LEDs on KeypadLinc will brighten to 100% 
3)  Press and hold KeypadLinc’s Set Button again until it beeps again 
 
KeypadLinc’s Scene button LED will continue blinking 
4)  Tap KeypadLinc’s Set Button 
 
KeypadLinc’s Scene button LED will continue blinking 
5)  For each Responder you are removing 
a.  If a KeypadLinc button, tap button 
b.  Press and hold Responder’s Set button until it beeps (or LED flashes) 
6)  After all Responders have been removed, Tap KeypadLinc’s Set Button 
 
KeypadLinc’s Scene button’s LED will stop blinking 
 
 
 
KeypadLinc’s LEDs will return to normal brightness 
7)  Test Scene by tapping Scene button a couple of times  
 
All the Responders removed will not respond  
Synchronized Scenes
 (formerly “Cross-Linking”) 
Synchronized Scenes are Scenes where all members stay synchronized. Common examples include 3-
way lighting circuits and Scenes with a single Load bearing device. 
For our example we will Synchronize 
Scenes on 2 SwitchLincs and identify them as A and B.  
 
Example: 2 Switch Circuit 
1)  Turn both switches/dimmers on – to the desired (and same) Scene level 
2)  Press and hold Switch A’s Set button until it beeps (or LED blinks) 
 
 
 
Switch A’s LED will blink 
3)  Press and hold Switch B’s Set button until it double-beeps (or LED flashes) 
 
 
 
Switch B will (Beep)-(Beep) and its LED will flash once 
 
 
 
Switch A will (Beep)-(Beep) and its LED will stop blinking 
4)  Press and hold Switch B’s Set button until it beeps (or LED blinks) 
 
 
 
Switch B’s LED will blink 
5)  Press and hold Switch A’s Set button until it double-beeps (or LED flashes) 
 
 
 
Switch A will (Beep)-(Beep) and its LED will flash once