Chapter 4     Signal Connections
 National Instruments Corporation
4-33
AT-MIO/AI E Series User Manual
Figure 4-14.  Typical Pretriggered Acquisition
SCANCLK Signal
SCANCLK is an output-only signal that generates a pulse with the 
leading edge occurring approximately 50 to 100 ns after an A/D 
conversion begins.  The polarity of this output is software selectable but 
is typically configured so that a low-to-high leading edge can clock 
external analog input multiplexers indicating when the input signal has 
been sampled and can be removed.  This signal has a 400 to 500 ns pulse 
width and is software enabled. Figure 4-15
 
shows the timing for the 
SCANCLK signal.
Figure 4-15.  SCANCLK Signal Timing
EXTSTROBE* Signal
EXTSTROBE* is an output-only signal that generates either a single 
pulse or a sequence of eight pulses in the hardware-strobe mode.  An 
external device can use this signal to latch signals or to trigger events.  
In the single-pulse mode, software controls the level of the 
Don't Care
0
1
2
3
1
0
2
2
2
TRIG1
TRIG2
STARTSCAN
CONVERT*
Scan Counter
t
w
t
w
= 400 to 500 ns
t
d
= 50 to 100 ns
t
d
CONVERT*
SCANCLK