Lennox striker sws160 사용자 설명서

다운로드
페이지 32
17
       WARNINGS
The  blower  must  be  plugged  directly  into  a  properly 
grounded three-prong receptacle, 120 VAC, 60 Hz, single 
phase. Do not cut or remove the grounding prong from 
this plug.  Do not route power cord under or in front of 
appliance.
Installation must be in accordance with National Elec-
trical Code, ANSI/NFPA 70 - latest edition.  In Canada, 
the current CSA C22-1 Canadian Electrical Code - latest 
edition.
DANGER: Disconnect power before servicing blower.
In the event that you remove the blower for any reason, 
make sure a cover plate (available from Lennox Hearth 
Products) is installed before using the heater. Excessive 
rear wall temperatures will result if the stove is burned 
without the cover plate. The cover plate is not necessary 
if a blower has never been installed because a knock-out 
will be in place to act as the cover.  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 18 - Blower Wiring Schematic
ROOM AIR
BLOWER
SPEED
CONTROL/OFF
TWO POSITION
SWITCH
MANUAL/TEMPERATURE
AUTO-RESET
TEMPERATURE
SWITCH N/O
POWER CORD
3-RED
3-RED
YLW
BLK
WHT
4-GRN
1-BRN
1-BRN
4-GRN
3-RED
NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION
Blower Operation Guidelines
While in auto operation mode, the blower will turn off and on based on 
the temperature of the appliance.  Auto operation ensures there is suffi-
cient heat build-up to warm the air being moved by the blower before the 
blower is turned on.  Likewise, when the appliance cools off, the blower 
is turned off to prevent circulating cool air. Depending on the size and 
intensity of the fire it may be necessary to adjust the blower speed ac-
cordingly to ensure un-interrupted blower operation. For example a small 
fire may require a slower blower speed to keep the heat output by the 
blower consistent.  If the blower is operated in manual mode, it may be 
necessary to adjust the blower speed as the fire begins to burn down and 
the appliance is no longer hot enough to effectively heat the air moved 
by the blower.  If the air coming from the blower feels cool, one should 
either decrease the blower speed or stoke the fire to build up more heat.
NOTE: Turn blower off before opening the door to load the fuel.
BLOWER OPERATION
Figure 19 - Blower Controls
Blower Speed Control 
Knob (rheostat)
Manual / Auto
Rocker Switch
Blower Operation
The  blower  can  be  operated  manually  or  automatically  (blower  will 
turn on when the stove is hot and turn off when the stove is cool).  
The rocker switch on the control panel allows you to select between 
manual operation or automatic operation as follows (see Figure 19): 
 
MANUAL OPERATION:  Turn rocker switch to the “MANU-
AL” position and adjust rheostat knob to the desired speed. The blower 
will have to be manually turned “OFF” by rotating the rheostat knob 
clockwise until it clicks.
 
AUTO OPERATION: Turn rocker switch to the “AUTO” posi-
tion and the rheostat to the ON position (rotate rheostat knob coun-
terclockwise until it clicks). When the stove warms up, the blower will 
automatically turn on (adjust rheostat knob to the desired speed set-
ting). When the stove cools down, the blower will automatically turn 
off.
Rheostat Operation -  The highest blower speed is obtained by turn-
ing the rheostat knob counterclockwise until it clicks “ON”, then rotate 
towards “HIGH” to increase blower speed.  Rotate the knob clockwise 
for a lower speed.  To turn off, continue to rotate the knob clockwise 
until it clicks “OFF.”