DMP Electronics XR500 사용자 설명서
XR500 Series Canadian Programming Guide
Digital Monitoring Products
31
SySTem oPTionS
9.19
WLS AUDIBLE: DAY
WIRELESS AUDIBLE
ANY DAY MIN
Wireless Audible Annunciation
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system (1-50). Press any top row key to select the keypad buzzer annunciation
method for wireless low battery and missing messages. Select ANY to enable
annunciation anytime. Select DAY to enable annunciation except during sleeping
hours (9 PM to 9 AM). Select MIN (minimum) to annunciate only Fire and Fire Verify
zones during daytime hours (9 AM to 9 PM). Default is DAY.
9.20
KEYPAD PANIC KEYS
ENABLED: NO YES
Enable Keypad Panic Keys
This option allows the two-button panic key operation selected at the keypad to
send the Panic, Emergency, or Fire message to the central station receiver. Select
YES to enable the two-button panic operation to operate. To disable the two-button
panic operation, select NO. Default is YES.
9.21
OCCUPIED
PREMISES: NO YES
Occupied Premises
For All/Perimeter or Home/Sleep/Away systems, select YES to allow the panel to
automatically disarm the interior area(s) when arming all areas and a perimeter
zone is not tripped during the exit delay. Select NO to disable this feature. Default
is YES.
Note: With a Home/Sleep/Away with Guest arming system, this feature only applies
Note: With a Home/Sleep/Away with Guest arming system, this feature only applies
to the main system.
9.22
ENHANCED ZONE
TEST: NO YES
Enhanced Zone Test
Select YES to allow enhanced zone test operation. The default is NO.
Enhanced operation allows:
Enhanced operation allows:
• Panic Test and Walk Test functions can be restricted to operate only during an
Area 32, Shift 4 schedule if programmed. If no schedule is entered, the walk
test always operates.
• A Verify message is sent each time a zone is tested. If a zone is tripped
multiple times, a Verify message is sent for each trip. This allows the Central
Station to record the number of devices per zone.
• The Verify message for each zone test is sent at the time the trip occurs
instead of at the end of Walk Test.
• The System Test Begin and System Test End Central Station messages indicate
the type of zone being tested. The System Test Begin message also includes
the user name and number.
9.23
Dual EOL
Select YES to enable the use of dual 1K EOL resistors on panel zones one to eight.
This zone operation is used for medium or high risk ULC Listed applications. Please
see Dual EOL section in the XR500 Series Canadian Installation Guide for complete
details. Select NO to disable this feature. Default is YES.
9.24
SEND 16 CHAR
NAMES: NO YES
Send 16 Character Names
This option allows central stations to select being sent either the first 16 characters
of the name field or the entire programmed name, up to 32 characters, for user
name, user profile, zone name, area name, output name, and group name.
Select YES to have the first 16 characters of the name field sent to the central
Select YES to have the first 16 characters of the name field sent to the central
station. Select NO to send the exact number of characters entered in the name field
from 1 up to the maximum of 32 characters. Default is YES.
Note: Using 32 character names increases the length of the DMP Serial 3 message
Note: Using 32 character names increases the length of the DMP Serial 3 message
from the panel to the receiver. The SCS-1R receiver does not require an update to
pass these messages to the Host Automation System of the Central Station. Before
using names longer than 16 characters, determine whether the Host Automation
System of your Central Station can accept 17 to 32 character names. If not, only use
16 character names.
DUAL EOL NO YES