National Instruments DIO 6533 사용자 설명서

다운로드
페이지 125
Chapter 5
Signal Timing
DIO 6533 User Manual
5-22
© National Instruments Corporation
Figure 5-19.  Long-Pulse Mode Output Timing
Parameter
Description
Minimum
Maximum
Input Parameters
t
rr*
REQ pulse width
75
t
r*r
REQ inactive duration
75
t
ar
ACK to next REQ
0
Output Parameters
t
aa*
ACK pulse width
125
1
t
r*do
REQ inactive to new output data
(with REQ-edge latching)
0
50
t
rdo
REQ to new output data
(with REQ-edge latching disabled)
0
t
doa
Output data valid to ACK 
(with REQ-edge latching disabled)
25
1
 
t
aa* 
(min)
 
= 125 + programmable delay
All timing values are in nanoseconds.
REQ
ACK
Output Data
(REQ-edge latching)
Output Data
(REQ-edge
latching disabled)
tr*r
tr*do
tdoa
tar
taa*
trr*
trdo