Figure 5-22.  Trailing-Edge Mode Input Timing
Parameter
Description
Minimum
Maximum
Input Parameters
t
rr*
REQ pulse width
75
t
r*r
REQ inactive duration
75
t
dir*
Input data setup to REQ inactive
(with REQ-edge latching)
0
t
r*di
Input data hold from REQ inactive
(with REQ-edge latching)
10
t
dir
Input data setup to REQ
(with REQ-edge latching disabled)
0
t
adi
Input data hold from ACK
(with REQ-edge latching disabled)
0
Output Parameters
t
aa*
ACK pulse width
225
1
275
2
t
a*r*
ACK inactive to next REQ inactive
0
1
 
t
aa*
 (min)
 
= 225 + programmable delay
All timing values are in nanoseconds.
2
 t
aa*
(max) = 275 + programmable delay
REQ
ACK
Input Data
(REQ-edge latching)
Input Data
(REQ-edge
latching disabled)
tdir*
tr*r
tdir
taa*
ta*r*
trr*
tr*di
tadi
tadi