Operations
Calibrate the Print Engine
57518L-001 Rev. A
3/18/05
170PAX4 Maintenance Manual
101
Calibrate the Print Engine
Calibrate the print engine when it is first put into service. Calibration allows the print engine to 
establish the proper settings for the specific media and ribbon used in your application. You 
may calibrate the print engine at other times as needed. 
 shows the different methods 
for calibration.
Table 10 • Types of Calibration
Type of Calibration
Description
When/How It Occurs
Auto-calibration 
The print engine automatically sets 
the value it detects for the spaces 
between labels.
Occurs at the following times:
• When the print engine is first 
turned on if CALIBRATION is 
selected for 
MEDIA
 
POWER
 
UP
 
(see 
• When the print engine feeds media 
after the printhead is closed if 
CALIBRATION is selected for 
HEAD CLOSE
 (se
).
• As part of both the sensor profile 
and media and ribbon sensor 
calibration procedures.
Long (Standard) 
Calibration 
The print engine does the following:
• feeds media and ribbon
• sets the values it detects for media 
length, media type (continuous or 
non-continuous), and print mode 
(thermal transfer or direct thermal)
• updates the sensor values
To perform a long calibration, do one 
of the following:
• Press PAUSE on the front panel to 
pause the print engine, and then 
press CALIBRATE.
• Select CALIBRATION for the 
MEDIA
 
POWER
 
UP
 or 
HEAD
 
CLOSE
 parameter (see 
 or 
Short Calibration
The print engine calibrates using the 
current sensor values rather than 
detecting the spaces between labels 
and resetting the sensors. This 
calibration sequence uses fewer 
labels than the long calibration 
sequence, but it is less reliable 
because the values that are stored in 
the sensors could be incorrect.
Select SHORT CAL for the 
MEDIA
 
POWER
 
UP
 or 
HEAD
 
CLOSE
 
).