ORIFICE SIZE/ALTITUDE ADJUSTMENT
SMOKE DETECTORS
CODES AND APPROVALS
THE GAS STOVE
Installation of these appliances are approved for installation in New York 
City in the US state of New York (MEA#:  138­07­E).
NEW YORK CITY, NEW YORK (MEA)
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
(Massachusetts Approval #G3-0806-6)
These appliances are approved for installation in the US state of Mas­
sachusetts if the following additional requirements are met:
•  Install this appliance in accordance with Massachusetts Rules and 
Regulations 248 C.M.R. Sec. 5.08 2(a) through 2(e).
•  Installation and repair must be done by a plumber or gas fitter licensed 
in the Commonwealth of Massachusetts.
•  The flexible gas line connector used shall not exceed 36 inches (92 
centimeters) in length.
•  The individual manual shut­off must be a T­handle type valve. 
Massachusetts Horizontal Vent Requirements 
In the Commonwealth of Massachusetts, horizontal terminations installed 
less than seven (7) feet above the finished grade must comply with the 
following additional requirements:
•  A hard wired carbon monoxide detector with an alarm and battery 
back­up must be installed on the floor level where the gas fireplace 
is installed.  The carbon monoxide detector must comply with NFPA 
720, be ANSI/UL 2034 listed and be ISA certified.
•  A metal or plastic identification plate must be permanently mounted to 
the exterior of the building at a minimum height of eight (8) feet above 
grade and be directly in line with the horizontal termination.  The sign 
must read, in print size no less than one­half (1/2) inch in size, GAS 
VENT DIRECTLY BELOW.  KEEP CLEAR OF ALL OBSTRUCTIONS.
Certification
Gas appliances must be tested and certified by a nationally recognized 
testing and certification laboratory to ANSI (American National Standard 
Institute) gas appliance safety standards.
This stove has been tested and certified by OMNI ­Test Laboratories to 
ANSI Z21.88 / CSA 2.33 Standard for Vented Gas Fireplace Heater and 
CGA 2.17­M91 and UL 307B Gas Burning Heating Appliances for Manu­
factured (Mobile) Homes in both USA and Canada.
It has met all necessary ANSI Standards and is fully certified for installa­
tion in any community. If there are any questions or if you need further 
substantiation either write to or call your Lennox Hearth Products dealer. 
If you have further questions, please contact Lennox Hearth Products.
Check all local building and safety codes before installation. The installation 
instructions and appropriate code requirements must be followed exactly 
and without compromise. In the absence of local codes the following 
standards and codes must be followed.
The  Installation must  conform  with  local  codes or,  in the absence of 
local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54- 
latest edition, or the Natural Gas and Propane Installation Code, CSA 
B149.1- latest edition.
The appliance, when installed, must be electrically grounded and wired 
in accordance with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian 
Electrical Code, CSA C22.1 - latest edition.
•  Must conform with all local, state and national installation codes. In 
the absence of local codes, the installation must conform with National 
Fuel Gas Code ANSI Z223.1 ­ latest edition, also known as NFPA 54 
(In Canada, the current CAN/CSA  B149.1 installation code). Refer to 
the National Fuel Gas Code and local zoning and code authorities for 
details on installation requirements.
•  Mobile home installations must conform with the Mobile Home Con­
struction and Safety Standard, Title 24 CFR, Part 3280 (in Canada 
CAN/CSA Z240 MH), or, when such a standard is not applicable, the 
Standard for Mobile Home Installations, ANSI A225.1 ­ latest edi­
tion.
•  Must be vented directly to the outside in accordance with the latest 
edition of the National Fuel Gas Code and must never be attached to 
a chimney serving a separate solid fuel burning appliance.
•  Has been certified for use with either natural gas or propane.
•  Is not for use with solid fuels.
•  Is approved for sitting rooms and/or bedrooms.
For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice 
should be de­rated by 4% for every 1,000 feet to maintain the proper 
ratio  of  gas  to  air.  Improper  orifice  sizing  may  result  in  damage  and 
unsafe conditions. Changing the orifice should only be done by a quali­
fied service technician. Contact your Lennox Hearth Products dealer for 
proper orifice sizes.
Since there are always several potential sources of fire in any home, we 
recommend installing smoke detectors. If possible, install the smoke 
detector in a hallway adjacent to the room (to reduce the possibility of 
occasional false activation from the heat produced by the appliance).  If 
your local code requires a smoke detector be installed within the same 
room, you must follow the requirements of your local code. Check with 
your local building department for requirements in your area.