Namco Bandai Games 90500146 사용자 설명서
Page 45
5-1
Adjustment Switches
The Adjustment switches are located inside the coin door.
1.
Service Switch.
Press this switch to obtain game credits without incrementing the play meter.
2.
Test Switch
Slide the test switch ON to enter test mode.
Test mode allows testing and the changing of game settings.
(Refer to section 5-
2 "Test Mode" page 46
)
3.
Select Up/Down Switch
This switch is used to select the test required when in the Test Mode.
4.
Enter Switch
This switch is used to enter a selected test and to change settings within a test.
2 Amp Q/B
(Coin Fuse)
COIN COUNTER
TEST
SERVICE
TEST
SERVICE
ENTER
ENTER
UP
SELECT
DOWN
UP
SELECT
DOWN
PLAYER 1
PLAYER 2
Note: During link play mode where 2 players are playing at the same time, if
either Test Switch is switched on, the other players game screen will
return to the beginning phase of the current area being played and the
players game status (gained points, remaining bullets, remaining life
count) will be reset to default values.
The above condition will also occur if the link cable is disconnected,
or the power is removed from either PCB Assy.