2.  120/240 VAC loads — one load with a maximum total watt-
age requirement equal to the generator’s rated power output, 
and 240V across the generator output terminals; or two sepa-
rate loads, each with a maximum total wattage requirement 
equal to half of the generator’s rated power output (in watts), 
and 120V across the generator output terminals. Figure 1.2, 
shows the generator lead wire connections for 120/240 VAC 
loads. Also refer to the "Line Breakers" section for circuit 
breaker ratings.
This procedure should be done by an Authorized Service Dealer or 
other qualified installer.
Figure 1.2 - Connection for 120/240 Volts
T1
RED
T2
WHITE
T3
BLACK
GROUNDED NEUTRAL
STATOR POWER
WINDINGS
CB1
CB2
1.6 SPECIFICATIONS
1.6.1  FUEL REQUIREMENTS (GASOLINE)
This generator is equipped with a gasoline fuel system as standard 
equipment. Specific installations may provide either a separate fuel 
tank for the generator, or the generator may “share” the vehicle 
engine’s fuel tank.
1.6.1.1   Fuel Consumption (gph)
Model
10% Load
50% Load
100% Load
RV45G
.33
.45
.73
RV55G
.35
.55
.89
RV65G
.37
.65
.97
NOTE
Some installations using a “shared” fuel tank may have a gen-
erator fuel pickup tube that is shorter than the vehicle engine’s 
pickup tube.  Such an arrangement causes the generator engine 
to “run out of gas” while adequate fuel for the vehicle remains 
in the tank.
To reduce lead and carbon deposits use high quality UNLEADED 
gasoline with the generator. Leaded REGULAR grade gasoline is an 
acceptable substitute.
NOTE:
Using unleaded gasoline contributes to longer engine valve life by 
reducing lead and carbon deposits.
n
 
 The manufacturer does not recommend 
using any gasoline containing alcohol (such 
as “gasohol”). If using any gasoline contain-
ing alcohol, it must not contain more than 
10 percent ethanol (Do not use E85), and it 
must be removed from the generator during 
storage. Do NOT use any gasoline contain-
ing methanol. If using gasoline with alcohol, 
inspect more frequently for fuel leaks and 
other abnormalities.
1.6.2  ENGINE OIL REQUIREMENTS
All oil should meet minimum American Petroleum Institute (API) 
Service Class SJ, SL or better. Use no special additives. Select the 
oil's viscosity grade according to the expected operating tempera-
ture (also see chart).
SAE 30 
• 
Î
 Above 32° F
10W-30 
• 
Î
 Between 40° F and -10° F
Synthetic 5W-30 
• 
Î
 10° F and below
S A E   3 0
S A E   3 0
S y n t h e t i c   5 W - 3 0
S y n t h e t i c   5 W - 3 0
1 0 W - 3 0
1 0 W - 3 0
Crankcase and oil filter capacity is approximately 1.4 L or 1.5 U.S. 
quarts. DO NOT use special additives. See sections "Checking the 
Engine Oil Level" and "Changing the Engine Oil and/or Oil Filter" for 
oil level check and filling procedures.
General Information