lift-master 1a4730 사용자 설명서

다운로드
페이지 2
© 1998, The Chamberlain Group, Inc.
114A1825C
All Rights Reserved
Electric Box
HOW TO ORDER REPAIR PARTS
OUR LARGE SERVICE ORGANIZATION
SPANS AMERICA
INSTALLATION AND SERVICE INFORMATION
ARE AVAILABLE 6 DAYS A WEEK
CALL OUR TOLL FREE NUMBER - 1-800-528-6563
Hours: (Mountain Std. Time)
6 A.M. to 6 P.M.  Monday Through Friday
7 A.M. to 3 P.M. Saturday
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE FOLLOWING INFORMATION:
PART NUMBER     DESCRIPTION      MODEL
NUMBER
ADDRESS ORDER TO:
THE CHAMBERLAIN GROUP, INC.
Electronic Parts & Service Dept.
2301 N. Forbes Blvd., Suite 104
Tucson, AZ 85745
Light Module/Brake Installation
If installing both a light control module and a brake, Light Module/Brake Adapter Kit (1A4385) is required.
Light Control Module Operation:
The green lights on the Option Board will turn on if the board is seated properly and the power is on. When the
door reaches the full open position, the timer circuit will be activated. The green lampholder will receive power. If
the timer has not been set, the red lampholder will receive power when the door starts to close and until close
limit is activated. If the timer has been set, the red lampholder will receive power as follows:
TIMER SETTING
RED LAMPHOLDER RECEIVES POWER
Greater than 10 seconds
10 seconds before door starts to close and
until close limit is activated.
Equal to 10 seconds
5 seconds before door starts to close and
until close limit is activated.
Less than 10 seconds
Approximately 1/2 of timer setting in seconds
before door starts to close and until 
close limit is activated.
802BS0802Z2
1C4708
Red
White
Black
Green
Light
Red
Light
Cable
Red
White
Black
Light
Box
L3
L2
L1
R7 D2
D1
Q2
LOAD
X
+24VDC
OUT
1
2
3
TB1-
Q3
Q1
R4
R2
D3
D4
R2
14LG418B
WARNING DEVICES BOARD
1
2
3
TB2-
RED
LT.
120V IN
GREEN
LT.
K1
R8
C1
R5
R1 R2
J1-
13
10
8
4
1
+24V
+5V
R6
Green Lights
24 VOLT DC
Terminals
1C4652
STEP 5:
Refer to Figures 1 and 2 and complete wiring
connections as follows:
Connect red wire to red light terminal on the PCB 
connector.
Connect black wire to green light terminal on the
PCB connector.
Connect white wire to L1 (NEUTRAL) on the
power 
terminal strip.
Connect black jumper from L2 (HOT) on the power
terminal strip to (120V IN) terminal on the PCB
connector.
STEP 6:
Install red and green lights. (Not provided) 
Use 75 watt maximum.
STEP 7:
Refer to your Owner's Manual Optional Settings
Section for Timer to Close programming procedure.