Like a fuel tank, the Oil Tank will also be listed by its engine location
— Oil Tank (P), Oil Tank (C) or Oil Tank (S).
When setting fluid level configuration for the other fluid types you will
When setting fluid level configuration for the other fluid types you will
be given the opportunity to assign the tank a number in case you have
more than one tank of that fluid type. The tanks will be listed with a
tank number of your choosing. By default, the tank number is set to 1.
The other fluid types will be displayed as BlkWtr Tnk (1, 2 or 3),
The other fluid types will be displayed as BlkWtr Tnk (1, 2 or 3),
FrshWtr Tnk (1, 2 or 3), LWell Tnk (1, 2 or 3) and WsteWtr Tnk (1, 2 or
3). If the EP-15 fluid level has not been configured, it will be listed as
Unfcg F Lev on the bus devices list.
NOTE:
NOTE:
The Fuel Remaining Source must be set to fluid level for the unit to
correctly display fuel level information. It is set to Engine/Fuel
Flow by default.
Fluid Level menu
The Fluid Level menu contains the following features: Configure,
The Fluid Level menu contains the following features: Configure,
Unconfigure, Reconfigure, Level Warning, Calibrate, Reset Calibration
and Reset Values. Calibration and Reset Calibration will be addressed
in the calibration portion of this section.
Caution
Caution
If you configure your fluid level for fuel, you will NOT be able to
get a fuel range reading. Fuel Range will NOT be calculated
with a fluid level sensor. It will only be calculated with an
engine interface, EP-10 Fuel Flow or EP-50 Storage Device.
get a fuel range reading. Fuel Range will NOT be calculated
with a fluid level sensor. It will only be calculated with an
engine interface, EP-10 Fuel Flow or EP-50 Storage Device.
To configure EP-15 Fluid Level for Fuel:
1.
Make sure the Fuel Remaining Source has been set to Fluid Level.
Press
MENU
, use the
UP
and
DOWN
keys to select
S
YSTEM
S
ETUP
and press
ENTER
.
2. Highlight
B
US
D
EVICES
and press
ENTER
to bring up the Bus Devices
list.
3. Select
3. Select
U
NFCG
F
L
EV
and press
ENTER
. The following message will
appear: Press Enter to configure Fluid Lev Snsr.
4. Press
4. Press
ENTER
and the Fluid Level configuration menu will appear.
5. Choose
F
UEL
and press
ENTER
, which will open the Select Tank menu
with up to three options: Port Tank, Center Tank and Starboard Tank.
The number of tank options depends on the engine-tank configuration
you chose during Boat Setup.
6. Select the tank connected to the fluid level you are configuring and
6. Select the tank connected to the fluid level you are configuring and
press
ENTER
. You will be taken back to the Bus Devices list, where the
tank will be displayed as Fuel Tank (P), Fuel Tank (C) or Fuel Tank
(S). Press
EXIT
repeatedly to return to the main display.