tRestrict: Restricted areas for the Top layer.
bRestrict: Restricted areas for the Bottom layer.
vRestrict: Restricted areas for vias.
Such restricted areas can already be defined in a device package (around,
for instance, the fixing holes for a connector, or for a flat-mounted tran-
sistor under which there should not be any tracks).
Wires drawn in layer 20, Dimension, are boundary lines for the Auto-
router. Tracks cannot be laid beyond this boundary.
Typical application: board boundaries.
An area drawn in layer 20 can also be used as a restricted region for all
signals. It should, however, be noted that this area should be deleted be-
fore sending the board for manufacture, since layer 20 is usually output
during the generation of manufacturing data.
Cost Factors and Other Control Parameters
The default values for the cost factors are chosen on the basis of our ex-
perience in such a way as to give the best results.
The control parameters such as mnRipupLevelmnRipupSteps etc. have
also been set to yield the best results according to our experience.
We want to emphasize, that we recommend working with the default
values. If you nevertheless do want to experiment with these parame-
ters, please consider the description of the cost factors in the following
section. In the case of many parameters even small alterations can have
large effects.
7.5 How the Cost Factors Influence the
Routing Process
Values between 0..99 are possible for each cost factor (cfXXX), but the
full range is not useful for all parameters. Sensible values are therefore
given with each parameter. The control parameters (mnXXX) accept
values in the range 0..9999. Reasonable figures are also provided under
each parameter.
cfBase.xx: 0..20
Base costs for one step on the corresponding layer. Recommendation:
outside layers (Top, Bottom) always 0, inside layers greater than 0.
144
EAGLE Manual