cfPolygon 0..30
Every step within a polygon is associated with this value. A low value al-
lows routing inside a polygon. The probability that the polygon is bro-
ken into several pieces is higher. A higher value causes the Autorouter
to make as few connections as possible inside a polygon.
mnVia 0..30
Controls the maximum number of vias that can be used in creating a
connecting track.
mnSegments 0..9999
Determines the maximum number of wire pieces in one connecting
track.
mnExtdSteps 0..9999
Specifies the number of steps that are allowed at 45 degrees to the pre-
ferred direction without incurring the value of cfExtdStep.
See also cfExtdStep.
7.6 Number of Ripup/Retry Attempts
Due to the structure of the Autorouter there are some parameters
which influence the ripup/retry mechanism. They are set in such a way
that they offer a good compromise between time demand and routing
result. The user should therefore only carefully change the values for
mnRipupLevelmnRipupSteps and mnRipupTotal when needed.
As a rule, high parameter values allow for many ripups but result in in-
creased computing times.
To understand the meaning of the parameters you need to know how
the router works.
To begin with the tracks are routed one after the other until no other
path can be found. As soon as this situation occurs, the router removes
up to the maximum number of already routed tracks (this number has
been defined with mnRipupLevel) to route the new track. If there are
eight tracks in the way, for example, it can only route the new track if
mnRipupLevel is at least eight.