Please note that changing the parameters before recalling will not influ-
ence the job, since it will have been saved together with the parameters
which were valid at the time of the initial Autorouter start.
When the Autorouter has finished, the routed board is saved as
name.b$$. You can rename it to name.brd and use it, for instance, if a
power failure occurred after the autorouting run and you could not save
the board file. This file is deleted automatically after the board has been
saved.
7.10 Information for the User
Status Display
During the routing, the Autorouter displays information on the actual
routing result in the status bar.
The displayed values have the following meaning:
Route:
result % (hitherto maximum, best data
Vias:
Number of vias
Conn.:
Connections total/found/not routable
Ripup:
No. of ripups/cur. RipupLevel/cur. RipupTotal
Signals: Signals found/signals handled/signals prepared
Connections means 2-point connections.
The significance of the various RIPUP options:
Number of ripups:
This indicates the number of connections that have already been routed
during the foregoing routing procedure that have been (can be) remo-
ved in order to be able to route new signals.
Current RipupLevel:
This indicates the number of connections that have been removed or
converted in airwires in order to lay the track for the current signal.
Current RipupTotal:
After a signal's routes have been ripped up it can be broken down into a
large number of two-point connections. These connections are then
routed again. This variable indicates the number of such two-point
connections still to be routed.