Simon Security System
10
Figure 3. Panel Mounting Hole Locations
4.
For wall mounting, insert anchors into holes where studs are not present.
5.
Install all screws and tighten gently.
Connecting Hardwire Devices
The panel has 5 screw terminals located on the upper-right corner of the circuit board 
(see Figure 3) for connecting AC power, sirens and/or hardwire detectors.
AC Terminals
Note  
All inputs and outputs are 
Class II power limited cir-
cuits.
These terminals are used for connecting a 9 VAC, 700 mA AC power transformer. For 
systems with no X10 modules, use transformer part no. 22-109. For systems with X10 
modules, use transformer part no. 22-TBD.
HWIN1, HWIN2, and DCOUT Terminals
These terminals are dual purpose and can be used for either siren or hardwire detector 
connections.
Note  
These terminals cannot pro-
vide both functions simulta-
neously.
Sirens
From the factory, these terminals are set up for siren operation with HWIN1 handling 
interior sirens (status and alarm sounds), HWIN2 handling exterior sirens (alarm 
sounds only), and DCOUT providing the positive (+) voltage.
Note  
The total current available 
from the DCOUT terminal is 
250 mA at up to 122° F (50° 
C).
With Option 53: Hardwire Siren Supervision turned on, sirens connected to HWIN1 
and HWIN2 are supervised and require a 4.7k resistor in the circuit. If either of these 
terminals is not used with Option 53 on, you must connect a 47k resistor between the 
unused terminal and DCOUT.
Hardwire Detectors
To set up HWIN1 and/or HWIN2 for hardwire detectors, make the required connec-
tions as described under “Wiring Hardwire Detectors,” then proceed to the “Program-
ming” section to add (learn) them into panel memory.
Wiring Interior Sirens
Panel terminal HWIN1 can be used for connecting interior sirens and activates for sta-
tus and alarm sounds.