Simon Security System
34
If this option is turned on, sirens connected to the panel terminals require an EOL 
resistor in the wire circuit (see “Installing the System” for siren supervision wiring). If 
this option is turned off, EOL resistors are not required whether sirens are connected 
or not.
Note  
For UL listed systems, this 
feature must be on and EOL 
resistors installed. Also for 
UL Listed systems, this fea-
ture must be on if Option 29: 
Panel Piezo Alarms is off.
¾
To turn on Hardwire Siren Supervision, press:
Add—Option #—53—DONE.
¾
To turn off Hardwire Siren Supervision, press:
Delete—Option #—53—DONE.
Option 54: Access Code Length (Default = 4)
Determines how many digits are in all access codes.
Turning on this option lets you set the access code length to 3, 4, 5, or 6 digits. Turning 
off this option resets the access code length to the default setting, resets Master, Utility 
1, and Utility access codes.
Read the following before changing this option.
This option affects all system access codes (Master, Utility 1, Utility 2, Panic, and 
User).
Changing the access code length changes the Master, Utility 1, and Utility 2 
access codes to their respective defaults as described in the following table.
Note  
Changing the Access Code Length clears/deletes any User Codes that were previously pro-
grammed. If the customer wants the Access Code Length changed, it should be set before 
programming any new (unprogrammed) access codes, whenever possible
¾
To change Access Code Length, press:
Add—Option #—54—3, 4, 5, or 6—DONE.
¾
To reset Access Code Length (to default), press:
Delete—Option #—54—DONE.
Option 55: Status Beep Volume (Default = 07)
Determines the panel piezo volume level for status sounds such as arming, trouble, 
and status beeps.
The volume can be set from 1 (lowest) to 10 (highest). Turning off this option resets 
the volume to the default setting. Entries must be 2 digits.
¾
To set Status Beep Volume, press:
Add—Option #—55—01 - 10—DONE.
Access Code Length Defaults
Setting
Default Code
3
Master—123
Utility 1—321
Utility 2—321
4
Master—1234
Utility 1—4321
Utility 2—4321
5
Master—12345
Utility 1—54321
Utility 2—54321
6
Master—123456
Utility 1—654321
Utility 2—654321