Dimensions of Countertop Cutout
Side View with an Oven
Min. 60
Min. 5 
Min. 40 
Flow of intake  
and exhaust
Oven
When Installing Above an Oven
 
The appliance may only be installed over a Panasonic oven. 
 
Allow for extra spaces for air circulation as shown below.
Dimensions
(measurement: mm)
R3 1
490
3 0
870
3
0
Building side wall
Countertop front
Min. 59
Building side wall
Building rear wall
Min.51
Min.600
Min.51
Min.51
Electrical Work
WARNING
Electrical work must be performed by a legally qualified electrician.
Min. 60
Min. 5 
Min. 40 
Oven
Electrical Requirements
Installation of the Earth Leakage Circuit Breaker
 
This appliance must be supplied with the proper voltage and frequency, and 
connected to an individual, properly earthed branch circuit, protected by a 
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
 
This appliance is not fitted with other means for disconnection from the supply 
mains having a contact separation in all poles that provide full disconnection 
under overvoltage category III conditions. Means for disconnection must be 
incorporated in the fixed wiring in accordance with the wiring rules.
 
Single-phase A.C. 220-240 V, 50 Hz electrical system must be used. (It is also 
possible to use a three-phase electrical system.) If connecting to aluminium 
wiring, use connectors approved for use with aluminium wiring.
 
Check with the local utilities for electrical codes applied in the area. Failure to 
wire the appliance according to governing codes may result in a hazardous 
condition. 
 
After installation, show the customer where the breaker for the appliance is 
located.
 
In accordance with the electrical wiring rules, incorporate the earth leakage 
circuit breaker in the home electrical wire.
 
Follow the specification of the earth leakage circuit breaker as follows. 
Rated current: 50 A (KY-B926SL / KY-B925GL), 40 A (KY-B915AL / KY-B915AB)  
Rated sensitivity current: 30 mA