Panasonic KYT937XLEPG 작동 가이드
![Panasonic](https://files.manualsbrain.com/attachments/8f677e63fb64cbb6c62d09e6242996e7631380a8/common/fit/150/50/34d700d3fb727c767799b2da5cc474b219c0a4312e9e3044c99491a2fb9a/brand_logo.png)
EN-
48
EN-
49
English
Electrical Work
WARNING
Electrical work must be performed by a legally qualified electrician.
Electrical Requirements
Installation of the Earth Leakage Circuit Breaker
■ This appliance must be supplied with the proper voltage and frequency, and
connected to an individual, properly earthed branch circuit, protected by a
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
■ This appliance is not fitted with other means for disconnection from the supply
mains having a contact separation in all poles that provide full disconnection
under overvoltage category III conditions. Means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.
■ Single-phase A.C. 220-240 V, 50 Hz electrical system must be used. (It is also
possible to use a three-phase electrical system.) If connecting to aluminium
wiring, use connectors approved for use with aluminium wiring.
■ Check with the local utilities for electrical codes applied in the area. Failure to
wire the appliance according to governing codes may result in a hazardous
condition.
■ After installation, show the customer where the breaker for the appliance is
located.
■ In accordance with the electrical wiring rules, incorporate the earth leakage
circuit breaker in the home electrical wire.
■ Follow the specification of the earth leakage circuit breaker as follows.
Rated current: 50 A*, rated sensitivity current: 30 mA
* If rated current is 40 A, please change to 7200 W under “Power Management”
in settings. (See page 12)
1. Turn off power.
Turn off power at the circuit breaker or remove fuses to the appliance branch circuit.
2. Connect the power cord.
Connect the power cord in accordance with all governing codes and ordinances.
■ Three-phase connection (380-415 V 3N~ 50 Hz)
Separate the L wires and connect them in accordance with the instructions
given in the following table and diagram:
Electrical cable
Wire connection
: Yellow / Green
(Connect to the earth terminal)
N: Blue, Cord No. 2 / 4 / 6
N: Blue, Cord No. 2 / 4 / 6
L: Black, Cord No. 1 / 3 / 5
(Connect to the live terminal)
Electrical Work
Electrical Connections
■ Single-phase connection (220-240 V ~ 50 Hz)
Connect the wires in accordance with the instructions given in the following
table and diagram:
Electrical cable
Wire connection
: Yellow / Green
(Connect to the earth terminal)
N: Blue, Cord No. 2 / 4 / 6
N: Blue, Cord No. 2 / 4 / 6
L1: Black, Cord No. 1
L2: Black, Cord No. 3
L3: Black, Cord No. 5
(Connect to the live terminal)
N
L
L1
L2
L3
N