Panasonic PTD7600 매뉴얼

다운로드
페이지 14
3. Command Format 
 [STX] AD**:C1 C2 C3:p1p2p3…pn (Voluntary length) [ETX]     
(note) Parameters after ':' to be added upon necessity.  
 
First 5 alpha numeric after STX("AD**:"(** is ID#))designates ID,  
followed by 3 alpha numeric codes which act Commands,  
then followed by “ETX” for indicates end.  
 
ID# is ruled as follows 
 
ADnn(ASCII 4 characters) 
 
 
nn : 01- 64 
 Individual addresses 
                        0A-0Z  Group ID 
                        ZZ 
 Address to all equipments (ID AL) 
 
 
4.
 
Control by R
S-232C 
CPU in the projector would act immediately after it receives RS232C Command codes. 
When the projector is in the stand-by mode, it only accepts “Power-ON” command. 
(In the practical operation at Stand-by Mode, it would receive the command codes 
 and eco backs as the normal communication ended.) 
Key-Repeat function does not work in the RS232C control. 
In case multiple commands are being sent, first receive the eco-back  
of the previous command and then the next command can be transformed. 
When the invalid command is received, the response from the projector would be 
 
[STX] ER401 [ETX] 
(Ref)[STX] ER N1 N2 N3 [ETX] 
N1 shows product category,  N1 = 4  means TV Display category. 
N2 N3 shows error types, N2 N3 = 01 means  
“Invalid Command”(Machine did not react for it).