Weed Instrument 2C31-LC-MM/MM Ring Module 사양 가이드

다운로드
페이지 6
EOTec 2000 ControlNet™ Fiber Optic SHR/DSHR Communications Modules
Rev 1, Pub: 2C13/2C32 -11-07
Weed Instrument Company, Inc.
707 Jeffrey Way, P. O. Box 300
Round Rock, Texas 78680-0300
Phone: 512-434-2850, Fax: 512-434-2851
E-Mail: fiberop@weedinstrument.com
www.weedinstrument.com
Specifications subject to change without notice.
Self-Healing Ring Modules (SHR):
2C31-LC-MM/MM
ControlNet™ Self-Healing Ring (SHR) 
Fiber Optic Communication Module, 
Multi-mode, LC connector
2C31-LC-SM/SM
ControlNet™ Self-Healing Ring (SHR) 
Fiber Optic Communication Module, 
Single Mode, LC connector
Dual Self-Healing Ring Modules (DSHR):
2C32-LC-MM/MM
ControlNet™ Dual Self-Healing Ring 
(DSHR) Fiber Optic Communication 
Module, Multi-mode, LC connector
2C32-LC-SM/SM
ControlNet™ Dual Self-Healing Ring 
(DSHR) Fiber Optic Communication 
Module, Single Mode, LC connector
Accessories:
2LNK-1M
Link cable (for DSHR only), 1 meter
62-LC-ST-2M
Duplex Fiber Patch Cord, MM 
62.5/125μm, LC-ST, 2 meter
62-LC-LC-2M             Duplex Fiber Patch Cord, MM 62.5/125 
μm, LC-LC, 2 meter
62-LC-SC-2M             Duplex Fiber Patch Cord, MM 62.5/125 
μm, LC-SC, 2 meter
50-LC-ST-2M             Duplex Fiber Patch Cord, MM 50/125 
μm, LC-ST, 2 meter
50-LC-LC-2M             Duplex Fiber Patch Cord, MM 50/125 
μm, LC-LC, 2 meter
50-LC-SC-2M             Duplex Fiber Patch Cord, MM 50/125 
μm, LC-SC, 2 meter 
9-LC-ST-2M
Duplex Fiber Patch Cord, SM 9/125μm,
LC-ST, 2 meter
9-LC-LC-2M               Duplex Fiber Patch Cord, SM 9/125μm,
LC-LC, 2 meter
9-LC-SC-2M               Duplex Fiber Patch Cord, SM 9/125μm,
LC-SC, 2 meter
Dual Remote Power
Alarm Relays
Sets an alarm when either input has a
power fault
Ordering Information
Small Form-Factor Pluggable (SFP)
Easy to remove 1310nm Fiber Optic Transceivers for 
both Single Mode and Multi-Mode applications
Standard ControlNet BNC
For a quick connection into any network
High Resolution LEDs
Simplify local diagnostics
Real Time 4-20mA Outputs
Measures light intensity on both 
Fiber 1 & 2 to report real time optical
fiber deterioration
Fiber 1 and Fiber 2 
Remote Alarm Relays
Sets an alarm when either optic fiber has
a communications fault
Dual +15 to 30VDC
Power Inputs
Dual power inputs to insure a constant
power source
Dual Channel Link Cable
Easily connects communication between
optic fiber rings
Remote Link Alarm Relay
Sets an alarm when the dual channel link
has a communication fault
Remote Global Alarm Relay
Sets a single alarm when any power or
communication fault occurs in either
fiber communication ring
Model 2C32