Cisco Catalyst 4500 1300 WAC Power Supply (PoE) 사양 가이드
© 2005 Cisco Systems, Inc. All rights reserved.
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com.
Page 7 of 12
1300W ACV
(part number
PWR-C45-1300ACV)
2800W ACV
(part number
PWR-C45-2800ACV)
1400W DC-P
(part number
PWR-C45-1400DC-P)
4200W ACV
(part number
PWR-C45-4200ACV)
2500W
(part number
PWR-4502)
IEEE 802.3af-
Compliant
Yes
Yes
Yes
Yes
Yes
Input Current (Rated)
16A @ 100 VAC
7A @ 240 VAC
16A @ 200 VAC
Data: 31A @
-60VDC
Inline: 180A @
-48VDC
2x 12A @ 100 VAC
or
2x 12A @ 200 VAC
15A @ 200 VAC
Output Current (Data)
12V @ 84.7A
3.3V @ 12.5A
12V @ 113.3A
3.3V @ 12.1A
12V @ 120A
3.3V @ 10A
12V @ 115.3A
3.3V @ 12.5
-52 VDC @ 50A
(total output per
supply)
(total output per
supply)
Output Current (PoE)
-50V @ 16.7A
-50V @ 28A
-48/-60VDC @ 140A
-50V @ 77.1A
(200V)
-50V @ 38A (100V)
-52 VDC @ 50A
(total output per
supply)
Output Power
Redundant Mode
(Data)
1000W + 40W
1360W + 40W
1367W + 40W
1383W + 40W
Up to 1400W
(through DC supply)
Output Power
Redundant Mode (PoE)
800W maximum per
power supply
1400W maximum per
power supply
Up to 7500W (minus
the power consumed
for data)
3855W (200V)
1900W (100V)
2500W per supply
(minus the power
consumed for data)
Output Power
Combined Mode (Data)
1667W
2473W
2267W
2766W
—
Output Power
Combined Mode (PoE)
1333W (maximum)
2333W
7280W
7710 (200V)
3800 (100V)
—
Heat Dissipation
1568 BTU/hour
2387 BTU/hr
Data only: 1591
BTU/hr
Data and voice: 2905
BTU/hr
3580 BTU/hr
1210 BTU/hr per
power supply
Holdup Time
20 ms
20 ms
4 ms
20 ms
20 ms
Number Of 802.3af
Class 2 Powered
Devices Supported
102
179
384
384 PDs (200V)
241 PDs (100V)
318 PDs (per unit)
Number Of 802.3af
Class 0 And 3 Powered
Devices Supported
46
80
384
222 PDs (200V)
109 PDs (100V)
144 PDs (per unit)