1300W ACV 
(part number 
PWR-C45-1300ACV) 
2800W ACV 
(part number 
PWR-C45-2800ACV) 
1400W DC-P 
(part number 
PWR-C45-1400DC-P) 
4200W ACV 
(part number 
PWR-C45-4200ACV) 
2500W 
(part number 
PWR-4502) 
IEEE 802.3af-
Compliant 
Yes 
Yes 
Yes 
Yes 
Yes 
Input Current (Rated) 
16A @ 100 VAC 
7A @ 240 VAC 
16A @ 200 VAC 
 
Data: 31A @ 
-60VDC 
Inline: 180A @ 
-48VDC 
2x 12A @ 100 VAC 
or 
2x 12A @ 200 VAC 
15A @ 200 VAC 
Output Current (Data) 
12V @ 84.7A 
3.3V @ 12.5A 
12V @ 113.3A 
3.3V @ 12.1A 
12V @ 120A 
3.3V @ 10A 
12V @ 115.3A 
3.3V @ 12.5 
-52 VDC @ 50A 
(total output per 
supply) 
Output Current (PoE) 
-50V @ 16.7A 
-50V @ 28A 
-48/-60VDC @ 140A 
-50V @ 77.1A 
(200V) 
-50V @ 38A (100V) 
-52 VDC @ 50A 
(total output per 
supply) 
Output Power 
Redundant Mode 
(Data) 
1000W + 40W 
1360W + 40W 
1367W + 40W 
1383W + 40W 
Up to 1400W 
(through DC supply) 
Output Power 
Redundant Mode (PoE) 
800W maximum per 
power supply 
1400W maximum per 
power supply 
Up to 7500W (minus 
the power consumed 
for data) 
3855W (200V) 
1900W (100V) 
2500W per supply 
(minus the power 
consumed for data) 
Output Power 
Combined Mode (Data) 
1667W 
2473W 
2267W 
2766W 
— 
Output Power 
Combined Mode (PoE) 
1333W (maximum) 
2333W 
7280W 
7710 (200V) 
3800 (100V) 
— 
Heat Dissipation 
1568 BTU/hour 
2387 BTU/hr 
Data only: 1591 
BTU/hr 
Data and voice: 2905 
BTU/hr 
3580 BTU/hr 
1210 BTU/hr per 
power supply 
Holdup Time 
20 ms 
20 ms 
4 ms 
20 ms 
20 ms 
Number Of 802.3af 
Class 2 Powered 
Devices Supported 
102 
179 
384 
384 PDs (200V) 
241 PDs (100V) 
318 PDs (per unit) 
Number Of 802.3af 
Class 0 And 3 Powered 
Devices Supported 
46 
80 
384 
222 PDs (200V) 
109 PDs (100V) 
144 PDs (per unit)