Cisco Module 48p 10/100 ENet RJ45 for Cat 6000 사양 가이드

다운로드
페이지 194
2-11
Catalyst 6500 Series Switch Module Installation Guide
78-15725-02
Chapter 2      Preparing for Installation
Determining Cable Distances
Figure 2-2
Patch Cord Installation
Differential Mode Delay
When an unconditioned laser source designed for operation on a single-mode 
fiber (SMF) cable is directly coupled to a multimode fiber (MMF) cable, 
differential mode delay (DMD) might occur. DMD can degrade the modal 
bandwidth of the fiber-optic cable causing a decrease in the link span (the distance 
between the transmitter and the receiver) that can be reliably supported.
The Gigabit Ethernet specification (IEEE 802.3z) outlines parameters for 
Ethernet communications at a gigabit-per-second rate. The specification offers a 
higher-speed version of Ethernet for backbone and server connectivity using 
existing deployed MMF cable by defining the use of laser-based optical 
components to propagate data over MMF cable.
Lasers function at the baud rates and longer distances required for Gigabit 
Ethernet. 802.3z identifies the DMD condition that occurs with particular 
combinations of lasers and MMF cable. The results create an additional element 
of jitter that can limit the reach of Gigabit Ethernet over MMF cable. 
With DMD, a single laser light pulse excites a few modes equally within an MMF 
cable. These modes, or light pathways, then follow two or more different paths. 
These paths might have different lengths and transmission delays as the light 
travels through the cable. With DMD, a distinct pulse propagating down the cable 
no longer remains a distinct pulse or, in extreme cases, might become two 
independent pulses. Strings of pulses can interfere with each other making it 
difficult to recover data. 
DMD does not occur in all deployed fibers; it occurs with certain combinations of 
worst-case fibers and worst-case transceivers. Gigabit Ethernet experiences this 
problem because of its very high baud rate and its long MMF cable lengths. SMF 
cable and copper cable are not affected by DMD. 
To equipment
To cable plant
13089