Cisco CATALYST 6509 BUNDLE WITH 1300W AC POWER SUPPLY WITH FAN TRAY 사양 가이드

다운로드
페이지 54
1-40
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Chapter 1      Product Overview
  Catalyst 6509-NEB Switch
Table 1-16 Catalyst 6509-NEB Switch Specifications
Item
Specification
Environmental
Temperature, ambient
operating
32˚F (0˚C) to 104˚F (40˚C)
Note
The Catalyst 6500 series switches are equipped with internal air
temperature sensors that are triggered at 40˚C (104˚F) generating a
minor alarm and at 55˚C (131˚F) generating a major alarm.
Temperature, ambient
nonoperating and storage
–4˚F (–20˚C) to 149˚F (65˚C)
Thermal transition
0.5˚C per minute (hot to cold)
0.33˚C per minute (cold to hot)
Humidity (RH), ambient
(noncondensing) operating
5% to 90%
Humidity (RH), ambient
(noncondensing)
nonoperating and storage
5% to 95%
Altitude, operating
–197 to 9843 feet (–60 to 3000 m)
Shock and vibration
This switch complies with Network Equipment Building Systems (NEBS)
(Zone 4 per GR-63-Core) in the following areas:
Earthquake environment and criteria
Office vibration and criteria
Transportation vibration and criteria
Shock
Operational—5 G 30 ms, half-sine (IEC 68-2-27)
Non-operational—20 G, 7.5 ms, trapezoidal
Vibration
Operational—3 Hz to 500 Hz,
Power Spectral Density (PSD)-0.0005 G
2
/Hz at 10 Hz and 200 Hz.
5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
Acoustic Noise
56.4 to 75 dB. International Organization for Standardization (ISO) 7779:
Bystander position operating to an ambient temperature of 86˚F (30˚C).