xG Technology Inc. XMAXBSN25 사용자 설명서

다운로드
페이지 19
1
xG Technology Inc. Proprietary and Confidential Information
Cable Settings 
The xMAX BSN-250 VoIP Base Station is a three-sector, 18-channel system. Using the Web configuration 
interface menu, click 
RF Cable Settings 
to configure cable length and cable loss for each sector in order 
to calibrate the TX Power correctly. This screen is shown in Figure 6. After entering the appropriate values, 
click 
Apply
 to save settings, or 
Cancel
 to return to the prior settings.
RF Cable Length (ft): 
Specify the distance, in feet, from the RF connectors on the back of the BSN-250 to 
the antenna.
RF Cable Loss (dB/100ft): 
Specify the loss factor/multiplier in the cable.
Total Cable Loss (dB):
 Specify the total loss in the cable. This field is automatically populated when the RF 
cable length and loss have been entered. 
Figure 6: Web Configuration Interface – Cable Settings Screen