Eltav Wireless Monitoring Ltd. VDA1114 사용자 설명서

다운로드
페이지 12
   
 
 
ELTAV Wireless Monitoring Ltd. 
 
 
 
Page  12   of   12                                                                                                                                                               7 March 2010 
 
15 HaTa'asia St., Ra'anana, 43654, Israel 
Tel: +972-9-7440012, Fax +972-9-7440026  Cel: +972-52-8551234  email: 
Israel.kalman@eltav.com
   Web: 
www.eltav.com
   
 
Valve Device 
(VD) 
 
Sense Movement 
Duration 
Between 30 msec to 4 minutes 
Sector  
Quarter turn: - 10
0
 to +100
0
 
Resolution 
0.1
0
 
Accuracy 
±1
0
 
Calibration and setup on 
valve 
Using Operator Device (OD) with short range Low Frequency wireless 
communication between OD and VD.  
Battery 
2 X Lithium Tadiran ½ AA TL4902. Field replaceable. 
Battery Life  
5 years assuming one valve position change per hour and nominal 
configuration.  
Message timing 
Each message is sent by VD with real time stamp 
VD max Transmitted 
Power 
+3dBm.  
VD Antenna 
Internal +2 dBi peak. Optional external antenna F-SMA connector (VD 
mounted or remote). 
Communication range 
VD - VDR 
Open space – about 70m. 
In doors at non obstructed environment – about 25 m.  
Additional VD 
Measurements 
VD internal temperature, battery voltage and unit's house-keeping 
parameters. 
Valve Transition 
Measurement (optional) 
After 1
0
 move of valve, VD collects up to 64 readings of valve position every 5 
ms up to 9.6 sec (user selectable in discrete steps) and transmits them as a 
packet.  
 
Valve Device 
(VD) 
Cont. 
VD software upgrade 
Both the Zigbee stack and the MCU application can be upgraded through the 
Zigbee link (DOR – Download Over Radio).  
Case Material 
Nylon 12 with 50% glass beads, UV stable 
 
Environmental 
 
Operating Temperature 
(VD/VDR/TVDR) 
-40
0
C to 85
0
VD/VDR/TVDR sealing  
IP66 grade 
VD ATEX 
Category 2 / Division 1 - II 2 GD EEx ia IIC T6 (intrinsic safety Zone 1/21)