IMPORTANT: The installer of this radio equipment must ensure that the antenna is located or pointed such
that it does not emit RF field in excess of Health Canada limits for the general population. Consult Safety
Code 6, obtainable from Health Canada's website www.hc-sc.gc.ca/rpb.
that it does not emit RF field in excess of Health Canada limits for the general population. Consult Safety
Code 6, obtainable from Health Canada's website www.hc-sc.gc.ca/rpb.
7.1.3 ETSI (Europe)
The BOX860P module has been certified for use in European union countries according to ETSI EN 300 328
(Electromagnetic compatibility and Radio spectrum matters for equipment operating in the 2,4 GHz ISM
band using spread spectrum modulation techniques). This standard is harmonized within the European
Union and covering essential requirements under article 3.2 of the R&TTE-directive.
If the BOX860P module are incorporated into a product, the manufacturer must ensure compliance of the
final end-user product to the European harmonized EMC and low voltage/safety standards. A declaration of
conformity must be issued for the product including compliance references to these standards. Underlying
the declaration of conformity a technical construction file (TCF), including all relevant test reports and
technical documentation, must be issued and kept on file as described in Annex II of the R&TTE-directive.
Furthermore, the manufacturer must maintain a copy of the BOX860P module documentation and ensure
the final product does not exceed the specified power ratings, antenna specifications, and/or installation
requirements as specified in the user manual. If any of these specifications are exceeded in the final
product, a complete re-test must be made in order to comply with all relevant standards as basis for CE-
marking. A submission to notified body must be used only if deviations from standards have been found or
if non-harmonized standards have been used.