2. Using the number keys, enter the master PIN code. The Status LED flashes
green and one good beep is sounded. Programming mode is initiated.
3. Using the number keys, press 11. The Status LED flashes green and one good
beep is sounded.
4. To confirm the delete, press 09 again. Three beeps confirm that the number
is deleted. Programming mode automatically ends and the status LED turns
off.
off.
3.12 Programming the Arm Function
For the three arm options, Full Arm, Part Arm Day, and Part Arm night, you can
set the Arming action to operate according to one of the following:
set the Arming action to operate according to one of the following:
Arm button action
PIN code + Arm button action
To program the arm function:
1. Insert the Programming tool point into the Programming button. The Status
LED flashes red and one good beep sounds.
2. Using the number keys, enter the master PIN code. The Status LED flashes
green and one good beep is sounded. Programming mode is initiated.
3. Using the number keys, press 12. The Status LED flashes green and one good
beep is sounded.
4. To select the quick arm, using the number keys, press:
0 – Arm with PIN code + Arm button
1 – Quick arm with Arm button
Three beeps confirm that the Arm function is defined. Programming mode
automatically ends and the status LED turns off.
automatically ends and the status LED turns off.
For information on arming/disarming the EverGuard Express system, refer to
Arming and Disarming the System on page 22, 23.
Arming and Disarming the System on page 22, 23.
3.13 Setting Operational Status
The EverGuard Express control panel has the following operational states:
NTS - no transmission status
ITS – Test status
CCS - continuous cycle status (active state)
The EverGuard Express panel is provided with operation status set to NTS
communication.
communication.
When you are finished programming the EverGuard Express panel by using the
AM, it sends the configuration to the Monitoring Station. During this operation,
the operational status is changed from NTS to ITS. When you are ready to set the
EverGuard Express control panel to active state, you can switch the operational
status to CCS.
AM, it sends the configuration to the Monitoring Station. During this operation,
the operational status is changed from NTS to ITS. When you are ready to set the
EverGuard Express control panel to active state, you can switch the operational
status to CCS.