The manufacturer warrants the Linear Proportional Convector and components of the 
enclosed product against any defect in material or workmanship for a period of one year from 
the date of purchase, with the exception of the elements which are warranted to be free from 
defect in material and workmanship for ten years.  In full satisfaction of any claims under this 
Warranty the manufacturer will repair or replace without charge, in its factory or in the field as 
it alone may decide, any parts which in its opinion are defective.
The manufacturer shall not be responsible for any transportation or shipping costs in relation 
to such repair or replacement except as specifically assumed by it.  misuse of this product 
or repairs by persons other than the manufacturer’s authorized personnel without the 
manufacturer’s written approval will void this Warranty.
This Warranty is in lieu of all other warranties or conditions whether expressed or implied 
including but not limited to those of merchantability or fitness for purpose and shall constitute 
the sole remedy of the Purchaser and the sole liability of the manufacturer in respect of the 
sale of the product, whether in the nature of breach or breach of fundamental term, or of 
negligence or otherwise.
The manufacturer shall not be liable for any special, indirect or consequential damages or 
for any damages resulting from removal or replacement of a Linear Proportional Convector 
subject to warranty claim without the manufacturer’s authorization.
This Warranty is transferable by the original  consumer purchaser of the product.  Any claims 
under this Warranty must be submitted in writing to the Service manager, Dimplex North 
America Ltd., 1367 Industrial Rd., Cambridge, Ontario N1R 7g8, Canada.
 
Warranty
 
maintenance
 CaUTiOn:  Before removing the front cover for cleaning, make certain the 
power has been turned off at the circuit breaker panel.  
 CaUTiOn: Allow adequate time for the element and body casing to cool 
before attempting to work on the heater. 
The LPC series contain no moving parts. Since the appliance contains no 
moving parts little maintenance is required beyond vacuum cleaning. It is, 
however, essential that the Linear Proportional Convector is not operated with an 
accumulation of dust or dirt on the element, as this can cause a build up of heat 
and eventual damage. For this reason the Linear Proportional Convector must be 
inspected regularly, depending upon conditions and at least at yearly intervals.  
Once cleaning is complete replace the front cover and restore power.
  
Warning: The user can perform cleaning ONLY.  All other servicing should 
be performed by qualified service personnel.
When power is first supplied to the LPC the Setpoint Temperature will flash in the 
temperature display area.  At any time either the + or  - button can be pressed to 
have the temperature setpoint displayed again.
a. Setting/Temperature Display  
Pressing the + or - will increase or decrease the desired temperature for the room 
to be heated by 0.5° (in either °C or °F).
After 5 seconds the Setpoint Temperature will switch to display the intake 
temperature of the room.
!
 nOTE: Pressing the + and at the same time will toggle between °C and °F.
B. Economy Setting 
The Economy Setting can be used to change the Setpoint Temperature for a 
variable period of time.  By pressing the v the Economy Setting will be enabled 
- signified by the icon flashing.  After the Set Back Temperature has been set, the 
icon will become solid after three seconds and the Set Back Temperature will be 
enabled.
To return back to the Comfort Setting press the v button and the   icon will 
disappear and the   icon will appear. 
C. Set Back Temperature Setting 
The Set Back Temperature Setting is used during periods when the Economy 
setting feature is active.  This temperature adjustment can be set by pressing the 
v followed by the + or -.  
D. Comfort Setting 
The Comfort Setting icon will be displayed when the heater is in normal operation 
based on the Setpoint Temperature for the room.
!
 nOTE: Either the   or   icon will always be visible, dependent on the 
setting being used.
 Operation
Figure 5
B
E F
g
H
i
A - Setting/Temperature Display
B - Economy Setting Icon 
C - Set Back Temperature Setting
D - Comfort Setting Icon
E - Synchronized Icon
F - Lock Icon
g - Decrease Button
H - Increase Button
I - menu Button
a
C
D
heater.
inStallation With non metallic caBle tYPe nmD
Place Linear Proportional Convector on floor face up. use packaging to protect 
1. 
it if required.  Remove front panel and right hand end cap (Connection must be 
on right hand side). 
Insert wire through hit-lock connector and connect to heater lead wires, as 
2. 
shown in Figure 2.  Additional wire nuts are required.  Connect grounding 
wire to grounding method provided.  Place wires in to heater and replace front 
cover. (Figure 3)
Push cable back into wall as Linear Proportional Convector is being positioned 
3. 
against wall.  Linear Proportional Convector is approved for installation with 
3/4” (1.9 cm) carpeting. For thicker floor covering, raise heater accordingly.
With  Proportional Convector in position, run screws through pre-selected 
4. 
mounting holes.  Screw should be backed off 1/2 turn from snug position to 
allow free expansion and contraction of housing and to ensure quiet operation. 
(Figure 4)
inStallation With riGiD, e.m.t. conDUit or BX caBle 
Remove screw holding the end cover and remove the cover.
1. 
use suitable knockout for cable/conduit entrance.  Secure in place on plate. 
2. 
(Figure 2)
make electrical connections in the connection box, as shown in Figure 2.  
3. 
Replace covers and secure baseboard in position. 
E. Synchronized icon 
A wall mounted controller is available to control one or multiple Linear Proportional 
Convector Heaters within a 50’ (15 m) radius.  In order for the wall setter to have 
this function the Linear Proportional Convector and the Wall Setter need to be 
Synchronized.  
On the Linear Proportional Convector press and hold the v button for 3 
1. 
seconds, both the 
 and   icons will begin to flash.
Press the 
2. 
- , + and  then v, on the Linear Proportional Convector.
Within 10 seconds press any button once on the Wall Setter.
3. 
!
 note: There is a 3 second delay between pressing the last button the wall 
setter and the LPC.
!
 note: To desynchronize a Linear Proportional Convector from the 
synchronized Wall Setter, on the Linear Proportional Convector:
Press and hold the 
1. 
v for 3 seconds.
Press the 
2. 
v+ and then -.
Nothing will need to be done to the Wall Setter.
F. Lock icon 
The Linear Proportional Convector Heater has a Button Lock feature, to prevent 
settings from accidentally being changed.
Press and hold the 
1. 
v for 3 seconds.  Both the 
 and   Icons will begin 
to flash.
To Enable:
2. 
 Within 5 seconds press +, then -, then +, then -.  The   icon 
will now be visible.
To Disable: Within 5 seconds press -, then +, then -, then +.  The   icon 
will not be visible. 
!
 note: The LPC can be locked in either the Comfort or Economy Setting.  
Ensure that the desired icons are present when locking is complete.