CLINICAL WARNINGS 
 
Diode  laser  radiation,  like  Nd:YAG  laser  radiation,  penetrates  significantly 
deeper  than  CO
2
  or  argon  lasers.    Caution  should  be  employed  until  the 
biological  interaction  of  the  laser  energy  with  tissue  is  fully  understood  by  the 
operator. 
Tissue damage could occur if excessive Power/Fluence is used.  Use low power 
and short pulse duration settings until fully familiar with instrument capabilities 
and tissue response. 
 
 
 
 
 
 
 
As with any conventional surgical operations, adverse reactions may occur 
following treatment. 
 
 
 
 
 
Use  cautiously  with  patients  who  have  had  difficulty  with  previous  laser 
procedures. 
The DIOMED DELTA 15/30 should be used only on tissue that is fully 
observable. Do not use the laser if the desired field is not visible, either directly 
or via an imaging modality such as ultrasound. 
 
 
Do not use coaxial gas/air coolant for non-contact fibers when there is a risk of 
air/gas embolism. 
Do not use the laser close to large blood vessels or in highly vascularised areas, 
except when these are the target for the laser treatment. 
When performing endoscopic surgery it is vital for the surgeon to appreciate that 
the  view  provided  to  the  surgeon  is  monocular  (not  binocular)  and  depth 
perception  is  decreased.    Experience  and  training  in  laparoscopic  techniques 
are strongly recommended prior to clinical use. 
During ENT procedures, laser safe endotracheal tubes should be used.