Shanghai Huace Navigation Technology LTD. A01024 사용자 설명서

다운로드
페이지 27
 
 
3.2 Configuring  the  Rover  Station  via  LandStar  7 
Software 
3.2.1 Receiving Static Data 
(1) 
Power on the receiver. 
(2) 
Run  LandStar  7  on  the  controller  →  create  a  new  project  or  open  an  existing 
project → establish the connection with the receiver via Bluetooth. 
(3) 
On the Static Setting screen, set parameters as need and then click Set to finish. 
3.2.2 Receiving  Corrections  Using  Cellular  Modem  in  the 
Controller 
(1) 
Power on the receiver. 
(2) 
(3)
 
Run  LandStar  7  on  the  controller  →  create  a  new  project  or  open  an  existing 
project → establish the connection with the receiver via Bluetooth. 
(4)
 
On the Work Mode screen, choose PDA Network as DatalinkNtrip as Protocol
(5)
 
Input or choose the corresponding  Ntrip IP and Port, and then, click download 
icon 
  to get the source table. 
(6)
 
Click the location icon at the end of source table row; users can have a view of the 
distance between current position and a single station in source table interface. 
Given this table, users can choose the closest single station. 
(7)
 
Input User Name and Password
(8)
 
Configure the related parameters from the dropdown list or enter the value with 
the  soft  keyboard:  Data  Format,  Elevation  Mask,  PDOP  Limit,  Safe  Mode  and 
Iono Condition
Note: Select the Data Format the same as that of the base receiver. Turning on or 
off of RTCM 1021-1027 messages depend on messages from the mount point and 
user’s need. 
(9)
 
Click Save and give a name to this work mode. Then, accept the work mode. 
 
Users  can  conduct  surveying  work  after the  rover  receiver receives  correction 
data (with correction LED flashes once per second) and gets a fixed solution.