BMI Technologies Inc. RFVI 사용자 설명서

다운로드
페이지 85
G FORCE PLUS RF Instruction Manual 
 
 
Apr/08
 6 
Doc #RF1 Rev.9 
Component Changes or Modifications 
 
Changes or modifications not expressly approved by the party responsible for compliance could void the 
user’s authority to operate the G FORCE PLUS Vehicle Interface, G FORCE PLUS Data Logger, G 
FORCE PLUS RF Vehicle Monitor, G FORCE PLUS RF Host Transceiver, and G FORCE PLUS RF 
Zone Transceiver. 
 
 
RF Exposure Warning 
 
The following warning applies to the G FORCE PLUS Vehicle Interface, G FORCE PLUS RF Vehicle 
Monitor, G FORCE PLUS RF Host Transceiver, and G FORCE PLUS RF Zone Transceiver: 
 
WARNING:  This device meets the FCC/IC requirements for RF exposure when the antenna used for 
this transmitter has a separation distance of at least 20 cm from all persons and must not be co-located or 
operating in conjunction with any other antenna or transmitter which is closer than 20 cm. 
 
The installer of this radio equipment must ensure that the antenna is located or pointed such that it does 
not emit RF field in excess of Health Canada limits for the general population as indicated by Safety Code 
6.  
 
 
DATA LOGGER TUTORIAL 
 
The Data Logger is a hand-held device used to transfer data between the Fleet Manager Software and a 
Vehicle Monitor.  The power source is a single 9-volt battery, stored in the battery compartment at the back of 
the unit.  A slot screwdriver opens the compartment for battery replacement. 
 
1.  Press {Enter} on the Data Logger to start its self-test.  The Data Logger will display: 
a.  “Selftesting…” 
b.  “SelfTest Passed Firmware 1V6” 
c.  “Action?(1-9)” 
2.  Press each number one at a time from {1} to {9} and watch the Data Logger display change for each 
selection: 
Number Display 
  Purpose 
1   
Events to PC 
 
Download Vehicle data to Software  
2   
Get Vehicle ID   
Get Vehicle ID from Software 
3   
Get Veh Settings 
Get Vehicle settings from Software 
4   
Events from Veh 
Collect Vehicle data (backup data collection method) 
5   
Prog Veh ID 
 
Program Vehicle ID to Vehicle Monitor 
6   
Prog Veh Settngs 
Program Vehicle settings to Vehicle Monitor 
7   
Date / Time 
 
Transfer Date / Time from Software to Data Logger to Vehicle 
8   
Hot Card List   
Transfer Hot Card List from Software to Data Logger to Vehicle 
9   
Clear Data 
 
Clear Data Logger data (ID’s, Settings, and Events) 
3.  Press {7}.  The Data Logger will display “Action?(1-9) Date / Time” 
4.  Press {Cancel}.  The Data Logger will revert to “Action?(1-9)” 
5.  Press {4}.  The Data Logger will display “Action?(1-9) Events from Veh” 
6.  Press {Enter}.  The DATA LOGGER will display “Ready for Events” 
7.  Do not press the keypad for one minute.  The Data Logger will automatically shut down.