EnOcean GmbH PTM210C 사용자 설명서

다운로드
페이지 17
USER MANUAL V0.9 
EnOcean GmbH 
Kolpingring 18a 
82041 Oberhaching 
Germany 
Phone +49.89.67 34 689-0 
Fax +49.89.67 
34 
689-50 
info@enocean.com 
www.enocean.com 
Subject to modifications 
PTM 210 / PTM 210C User Manual V0.9 
July 7, 2010 9:36 AM 
Page 11/18 
 
PTM 210 / PTM 210C 
 
Processor 
Converts the contact nipples’ status and pushed/released data from the power generator 
into a reliable and energy-efficient serial telegram structure. 
 
HF transmitter 
Sends the data in the form of a series of short radio signals. 
 
2.2  Contact Nipples Designation 
 
With 4 contact nipples, the PTM 210 offers 2 channels with 4 action states each (up-
per/lower nipple is pressed/released when activating the energy bow). The nipples’ desig-
nation is as follows: 
 
 
Contact nipple designation 
 
 
Radio signals of the PTM 210 device are event-controlled (energy bow is pressed/released) 
with contact nipple code (channel/state) and unique device identification (fixed 32-bit ID). 
When operating more than one nipple at the same time, note that PTM 210 sends multiple-
button code combinations: 
 
„ 
N-message: One or two contact nipples have been pressed when activating the energy 
generator Æ Message with nipple code and pressed/released event status of the energy 
bow is sent. 
„ 
U-message: No contact nipple was pressed when activating the energy generator, or 3 
or 4 nipples have been pressed Æ Message with pressed/released event status of the 
energy bow is sent and the information if either none or more than two nipples have 
been pressed. Note that it can’t be differentiated if 3 or if 4 nipples have been pressed.  
 
 
Due to the mechanical hysteresis of the energy bow, in most rocker switch device 
implementations, pressing the rocker sends an N-message and releasing the 
rocker sends a U-message! 
 
O
I
B
A
CHANNEL
STATE
O
I
B
A
CHANNEL
STATE