EnOcean GmbH PTM330U 사용자 설명서

다운로드
페이지 27
USER MANUAL 
V1.2 
© 2010 EnOcean  |  www.enocean.com 
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2  |  Page 12/27 
 
 
PTM 33X / PTM 33XC / PTM 330U 
U-message: 
 
DATA_BYTE3: 
 
7                                                                0 
BUTTONS 
PR 
Reserved 
 
BUTTONS 
(3 bit)  
Number of simultaneously pressed buttons, as following: 
0 = 0 Button
 
1 = not possible 
2 = not possible 
3 = 3 or 4 buttons 
4 = not possible 
5 = not possible 
6 = not possible 
7 = not possible 
 
PO 
(1 bit)  
Polarity, see table below 
Reserved 
(4 bit)  
 
 
STATUS: 
 
7                                                                0 
Reserved  T21  NU 
RP_COUNTER 
 
Reserved 
(2 bit)  
For future use 
T21 
(1 bit) 
NU 
(1 bit) 
NU=0  U-message. 
RP_COUNTER 
(4 bit) 
Repeater level: 0 is original message (not repeated) 
 
The polarity PO is defined as follows: 
      
 
 
3.7.2  User defined operation 
Via the configuration interface it is possible to define different content of DATA_BYTE3 and 
define if a N-message or U-message shall be sent. This allows for example to transmit 
other RORG=F6 telegrams, e.g. “Mechanical handle”, as described in the EnOcean Equip-
ment Profiles defined by EnOcean Alliance.  
For details please refer to the EnOcean Equipment Profiles 2.1 specification. 
http://www.enocean-alliance.org/fileadmin/redaktion/enocean_alliance/pdf/EnOcean_Equipment_Profiles_EEP2.1.pdf 
3.8  Transmit timing  
The setup of the transmission timing allows avoiding possible collisions with data packages 
of  other  EnOcean  transmitters  as  well  as  disturbances  from  the  environment.  With  each 
transmission  cycle,  3  identical  subtelegrams  are  transmitted  within  40  ms.  The  transmis-
sion of a subtelegram lasts approximately 0.7 ms. The delay between the three transmis-
sion bursts is affected at random. 
AC1 
AC2 
PO