TCM 300x / TCM 320x User Manual  |  Page 17/54 
 
 
TCM 300 / TCM 300C / TCM 300U 
TCM 320 / TCM 320C / TCM 320U 
3.6 
Mode selection 
 
The operating mode is defined at start-up of the module via a measurement of the voltage 
at ADIO0. 
 
 
 
Mode  ADIO0 (MODE_SEL) 
input voltage range 
Proposed com-
ponent values 
0% to 3.99% VDD 
R1: 0 Ohm 
R2: leave open 
R3: leave open 
C1: leave open 
4% to 11.99% VDD 
R1: 1k2 ±1% 
R2: 15k ±1% 
R3: 150k ±1% 
C1: 100p 
12% to 19.99% VDD  R1: 2k2 ±1% 
R2: 12k ±1% 
R3: 270k ±1% 
C1: 100p 
20% to 27.99% VDD  R1: 3k9 ±1% 
R2: 15k ±1% 
R3: 68k ±1% 
C1: 100p 
28% to 35.99% VDD  R1: 4k7 ±1% 
R2: 12k ±1% 
R3: 56k ±1% 
C1: 100p 
36% to 39.99% VDD  R1: 5k6 ±1% 
R2: 10k ±1% 
R3: 56k ±1% 
C1: 100p 
 
 
 
 
 
 
 
 
 
 
 
 
 
As long as IDs are stored in ID memory, the operating mode can only be changed 
after deleting all IDs from memory, e.g. via CLR! 
R2
R1
VDD
GND
ADIO0
R3
C1