EnOcean GmbH STM311C 사용자 설명서

다운로드
페이지 43
USER MANUAL V0.6 
© 2010 EnOcean  |  www.enocean.com
STM 31x / STM 31xC User Manual V0.6  |  Page 13/28
 
 
STM 31X / STM 31XC
2.6  Power management and voltage regulators 
 
Symbol  Parameter 
Conditions / Notes 
Min 
Typ 
Max 
Units
Voltage Regulators 
VDDR 
Ripple on VDD, where 
Min(VDD) > VON  
 
 
 
50 
mV
pp
UVDD 
Ultra Low Power supply   
 
1.8 
 
RVDD 
RF supply 
Internal signal only 
1.7 
1.8 
1.9 
DVDD 
Digital supply 
Internal signal only 
1.7 
1.8 
1.9 
Threshold Detector 
VON 
Turn on threshold  
 
2.3 
2.45 
2.6 
VOFF 
Turn off threshold  
Automatic shutdown if 
VDD drops below VOFF 
1.85 
1.9 
2.1 
 
Threshold detector 
STM 31x provides an internal ultra low power ON/OFF threshold detector. If VDD > VON, it 
turns on the ultra low power regulator (UVDD), the watchdog timer and the WAKE# pins 
circuitry. If VDD ≤ VOFF it initiates the automatic shut down of STM 31x. For details of this 
mechanism please refer to the Dolphin Core Description documentation. 
 
2.7  Configuration 
2.7.1 Configuration via pins 
 
The encoding input pins have to be left open or connected to GND in correspondence with 
the following connection schemes. These settings are checked at every wake-up. 
 
Wake-up cycle time 
 
CW_0 
CW_1 
Wake-up cycle time 
 
NC 
GND 
1 s ±20% 
 
GND 
NC 
10 s ±20% 
 
NC 
NC 
100 s ±20% 
 
GND 
GND 
No cyclic wake-up