If ORG = 7 (Telegram from a 4 Byte STM sensor):
DATA_BYTE3
Value of third sensor analog input (AD_2)
DATA_BYTE2
Value of second sensor analog input (AD_1)
DATA_BYTE1
Value of first sensor analog input (AD_0)
DATA_BYTE0 Sensor
digital inputs as follows:
7 0
Reserved
DI_3 DI_2 DI_1 DI_0
If ORG = 8 (Telegram from a HRC transmitter):
DATA_BYTE2..0 always = 0
DATA_BYTE3 as
follows:
7 0
RID UD
PR
SR Reserved
RID
(2 bit)
Rocker ID, from left (A) to right (D): 0, 1, 2 and 3
UD (1
bit)
UD=1
Æ O-button, UD=0 Æ I-button
PR (1
bit)
PR=1
Æ Button pushed, PR=0 Æ Button released
SR
(1 bit)
SR=1 Æ Store, SR=0 Æ Recall (see note)
Reserved
(3 bit)
for future use
Note: The bit SR is used only when the lower 3 Bits from ID_BYTE0 = 0b111 (scene
switch), and RID ≠ 0 (indicates that the memory buttons M0-M5 are operated in the hand-
held remote control).