SIP-DECT OM System Manual 
 
 
264 
7.15 OMM STANDBY 
To perform OMM standby, two OpenMobility Managers must be provided in an OMM network. One 
operates as the active OMM, and the other operates as the standby OMM.  
In the event that the RFP designated as the OMM fails, the other RFP, designated as the secondary 
OMM automatically assumes the role of the OpenMobility Manager. 
How OMM Standby works 
During system start-up, each RFP retrieves either one (if no standby OMM is configured) or two (if OMM 
Standby is configured) OMM IP addresses and both try to connect to each other. The active OMM 
serves all connections from RFPs or DECT phones. 
During normal operations, both the active and the standby OMM are in contact and monitor each other’s 
operational state. They continually exchange their current standby states and the standby OMM receives 
a copy of any configuration changes on the active OMM. As long as both OMMs are in contact, their 
databases are synchronized automatically. 
If the primary OMM fails, the OMM responsibilities are taken over by the standby OMM to maintain 
operation. A “No Standby” warning is displayed on the OMM web interface, indicating that there are no 
longer two functioning OMMs in the network or cluster. Configuration changes are made unsafely in this 
situation. 
If the active OMM fails, the inactive OMM recognizes this and begins to act as the active OMM, and 
starts the web service.  
If the connection between the two OMMs fails, the network or cluster essentially breaks into two 
operational parts. The standby OMM becomes the active OMM. At this point, the two OMMs cannot 
detect one another and, therefore, cannot synchronize. When the connection between the two OMMs is 
re-established, the synchronization of the OMMs forces one OMM to become the standby OMM again. 
Once the recently failed OMM returns to service and becomes the inactive OMM, it does not resume the 
role of active OMM. 
 
7.15.1 CONFIGURING OMM STANDBY 
Each RFP of the DECT system must be configured with two OMM IP addresses. Both OMM addresses 
can be either configured via DHCP (see section 7.5.1) or with the OM Configurator (see section 7.6). 
 
7.15.2 FAIL OVER SITUATIONS 
Fail over occurs when: 
• 
an OMM error occurs on the active OMM. 
• 
the RFP acting as the active OMM is shut down or rebooted at the SSH console. 
• 
the OMM is rebooted in the web browser menu. 
• 
the active OMM is unreachable. 
The standby OMM becomes the active OMM when:  
• 
the configured SIP Proxy/Registrar is reachable. 
• 
the other OMM has a larger IP Address while no OMM is active and both OMMs are in contact with 
each other (normally at system startup).