Q Global Solutions Electronics Corp. QGS300181406 사용자 설명서

다운로드
페이지 5
visual effect (on top left); if camera is not connected, Monitor will show black background 
and display GUI visual effect in he center. GUI doesn't function in "D" or "N" gear. 
     
 
 
 
4.2.2. For 2-sensor operation mode, sensors are supposed to be 
connected to  port  CL/CR on  FS  unit, GUI  will display two central sensors' pattern. GUI 
doesn't support 3-sensor mode. 
4.3 Sensor-diagnosis 
Once activated, GUI-OSD unit starts its diagnosis for sensor: 
 
1. each beep stands for one defective sensor.   
2. low pitch sound is for front sensors; while high pitch sound is for rear sensors; 
3. when both front and rear sensors are connected, front sensor diagnosis is conducted 
first.  
4. Note: if sensors only connects to CL/CR ports, FS unit will view this situation as 2-sensor 
operation mode and won't deliver defective warning beeps. 
4.4 Detection Sections 
There will be at most six curves showed on the screen, their section is 
180-150-120-90-60-40-00 (in cm), .   
 
When an object is detected, system will deliver alarming sound as well as graphic warning 
by showing the curves on the screen. 
 
Sound alarm: 
- As obstacle gets closer, system delivers higher frequency alarms, the beep becomes solid 
sound when it get closer than 60cm.   
- Low pitch for front sensors, high pitch for rear sensors. 
4.5 Switch Function 
Switch 1: