Advanced Card Systems Limited ACR1281U 사용자 설명서

다운로드
페이지 79
ACR1281U 
 
 
 Advanced Card Systems Ltd. 
Page 25 of 81 
12.  Read and Update the RC531 Register 
•  Read the Register = {E0 00 00 19 “Register No”} 
•  Response = {E1 00 00 00 01 “Current Value”} 
•  Update the Register = {E0 00 00 1A “Register No” “New Value”} 
•  Response = {E1 00 00 00 00} 
 
13. Go into Contactless EMV Terminal Loop 
•  Command = {0E 00 01 00 00} 
•  Response = {90“Current Value”} 
 
14. Go into Contact EMV Terminal Loop 
•  Command = {0E 01 01 00 00} 
•  Response = {E1 00 00 00 01 “Current Value”} 
 
 
15.  Read and Initial Card Insert Counter 
•  Read the Register = {E0 00 00 09 00} 
•  Initialize the counter = {E0 00 00 09 04 “ICC Counter (LSB)” “ICC Counter (MSB)” 
“PICC Counter (LSB)” “PICC Counter (MSB)”} 
Response = {E1 00 00 00 04 “ICC Counter (LSB)” “ICC Counter (MSB)” “PICC Counter 
(LSB)” “PICC Counter (MSB)”} 
•  Update the counter data to static storage unit = {E0 00 00 0A 00} 
 
 
16.  Initial RC531 Setting For PICC 
•  Read the Register = {E0 00 00 2F 00} 
•   
•  Update the Registers:  
E0 00 00 2F 13 BModeIndex RxAThres106 RxAThres212 RxAThres424 RxAThres848 
RxBThres106 RxBThres212 RxBThres424 RxBThres848 RxACtl106 RxACtl212 
RxACtl424 RxACtl848 RxBCtl106 RxBCtl212 RxBCtl424 RxBCtl848 CWAConductonce 
CWBConductonce 
 
•  Response:  
 
E1 00 00 00 13 BModeIndex RxAThres106 RxAThres212 RxAThres424 RxAThres848 
RxBThres106 RxBThres212 RxBThres424 RxBThres848 RxACtl106 RxACtl212 
RxACtl424 RxACtl848 RxBCtl106 RxBCtl212 RxBCtl424 RxBCtl848 CWAConductonce 
CWBConductonce 
 
 
Default value: 
  1. E0 00 00 2F 13 0B 8F AF 85 80 8F 8F 8F 8F 72 53 32 12 76 52 32 12 3f 3f