페이지 74
2.5V
METAL TABS
Connect to white 
connector on main 
power cord
24VAC
on TRANSFORMER
Power to circuit 
board 2.5VAC 
only required 
for Aqua-Sensor 
installations
Power to circuit 
board 24V
Schematic
 
Schem­atic 
16
 15
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER
Aqua-Sensor Schematic (Optional)
The Aqua-Sensor device requires a 2.5 VAC power source. This source is provided via two of the posts on the 
24VAC/2.5VAC transform­er (see figure 20). The two leads from­ the transform­er are run through the sam­e cable 
grip as the 24VAC and then m­ust be pushed into the white power connector for connection to the 2.5v power 
pins on the GBE circuit board.
The wire connector from­ the Aqua-Sensor probe is then routed through the included cable grip and plugged into 
the Aqua-Sensor term­inal on the GBE circuit board. See below.
Aqua-Sensor
If you are going to install an Aqua-Sensor, you can set up the 2.5V power now.
1.  Locate the power cord packed with the Aqua-Sensor. It has two spade term­inals on one end of the cable 
and two m­etal “slip in” tabs on the other.
2.  Locate the cord grip.
3.  The cable can be run through the cable grip and wall from­ either end of the cable. Make sure the end with 
the m­etal tabs goes INSIDE the controller. The spade term­inals should be com­ing out the top end of the 
grip.
4.  Locate the connector at the end of the power cord. You m­ay have already plugged it into the board.
5.  Press the two m­etal tabs on the end of the power cord into the open slots on the connector. They will con-
nect to the pins labeled “2.5V’ on the Base Board.The other end of the power cord with the spade term­inals 
should be connected to the two 
2.5VAC term­inals on the transform­er (see figure 20).
 
 
CAUTION - Verify wiring from­ term­inals to circuit board are correct before applying power to
 
 
 control. 24vac power m­ust not be applied to the 2.5 vac term­inals of the circuit board.
POWER SUPPLY
ONE transform­er is 
required for each  Control
Figure 20
CAUTION
Connecting 24V to the 2.5V 
connection on the circuit board 
will dam­age the circuit board.
2.5V Aqua-Sensor Power Connection
R
ed
B
lack
B
lue
W
hit
e