AQUASENSOR: Troubleshooting statistics. 
 z-Ratio (impedance ratio) - Number calculated by microprocessor on measured voltage 
values that are converted to a digital representation. This is the value that the control 
monitors in order to determine need for regeneration and salt rinse-out.
  z-Minimum (minimum impedance ratio) - Reference point that the Z-ratio is 
compared to, in order to initiate a regeneration. This number is reset after every successful 
regeneration.
  Increase Percent (impedance ratio increase) - During service, this number 
represents the percent increase or z-ratio over z-minimum.  A regeneration is initiated when 
it reaches 7.5% or more for at least 6 minutes. 
Press DOWN arrow to view the next statistic.
SBT SENSOR: Smart Brine Tank Probe troubleshooting statistics. 
The SBT probe has four sensors within it. The Check sensor screen displays the current status 
(opened = “OP”, or blocked =“BL”) for all four sensors. The expected outputs from the SBT probe 
inside the brine tank are shown in Table 1 below while the expected outputs from an SBT probe 
“in air” are shown in the Table 2.
Table 1 - Expected Readings on the Sensor/Diagnostic screen when the SBT probe is installed inside the brine tank
displays “BL” 
displays “OP” 
Salometer 
Brine at least 1 inch above the salt plate. 
Salt Level 
Normal Operation .– Salt level greater than 8” 
above the salt plate 
Salt level less than 8” above the salt plate 
Flow Rate #1 
Water level in brine tank is below salt plate 
Water level is brine tank is more than 1” 
above salt plate 
Flow Rate #2 
Water level is brine tank is more than 1” above 
salt plate 
Water level in brine tank is below salt plate 
Table 2 - Expected Readings from the SBT probe when the probe is just sitting in “air” (ie not installed in the brine tank)
Normally 
Probe Inverted 
Salometer 
“OP” 
“BL” 
Salt Level 
“OP” 
“OP” 
Flow Rate #1 
“BL” 
“OP” 
Flow Rate #2 
“OP” 
“BL” 
aquasensor
zratio  1.075
zminimum 1.070
0.75
% increase
sbt sensor
salometer=op
salt level=op
fr1=bl  fr2=op