Airspan Networks Inc ASMAX49 사용자 설명서

다운로드
페이지 56
Cabling The ProST 
27 
 
CONNECTING PROST TO SDA-1 
 
The ProST connects to the SDA-1 using a CAT 5 cable with 8-pin RJ-45 connectors on either 
end. The ProST provides a 15-pin D-type port for interfacing with the SDA-1. However, for 
allowing the use of RJ-45 connectors, your ProST kit includes a DB15-to-RJ45 adapter that can 
easily be attached to the ProST's 15-pin D-type port. 
The cable setup for ProST-to-SDA-1 connectivity is as follows: 
 Cable: Straight-through CAT 5 Ethernet cable 
 Connectors: 8-pin RJ-45 
 Connector pinouts: 
Wire color 
Wire 
pair 
Pin 
Function 
Blue/White 
+48 VDC 
Blue 
48 RTN 
Orange/White 
Rx+ 
Orange 
Rx-  
Green/White 
Tx+ 
Green 
Tx- 
Notes:  
• Only pins 1 to 6 are used. 
• Pins 7 and 8 should not be wired to the ProST end. 
• The wire color-coding described in the table is AS.MAX's standard for wire color-coding. 
However, if you implement your company's wire color-coding scheme, ensure that the 
wires are paired and twisted according to pin functions listed in the table above (e.g. Rx+ 
with Rx-). 
To connect the ProST to the SDA-1: 
1.
 
Attach the DB15 side of the DB15-to-RJ45 adapter to the ProST's 15-pin D-type port 
(female). 
2.
 
Plug the RJ-45 connector of the Category 5 Ethernet cable (not supplied) into the RJ-45 
port of the DB15-to-RJ45 adapter. 
3.
 
Plug the RJ-45 connector, at the loose end of the Category 5 Ethernet cable, into the 
SDA-1's RJ-45 port labeled RADIO