Aclara Power-Line Systems Inc. Y72553-1 사용자 설명서

다운로드
페이지 86
T W A C S
®
- O R I O N
®
  f o r   U M T   P r o d u c t s   U s e r   G u i d e  
63
Chapter 3 • Troubleshooting
Field Troubleshooting
Distribution Control Systems, Inc. has developed various software and hardware 
products for testing TWACS-enabled devices in the field and the meter shop. See 
this system.
The EMTR-3 has no field serviceable parts. It can only install, delete, or query 
installed ORION transmitters.
When necessary, the HHTR can be used to - 
• Install the Orion transmitter 
N
OTE
The HHTR can not communicate with the Orion transmitter.
• Query the EMTR for a remote installed list
• Delete Orion from the EMTR installed list
• Check EMTR status (Hardware & Firmware version)
A remote list query by the HHTR gives port-specific information for each installed 
Orion transmitter as follows:
• Serial Number & Service Type
• Acquisition Failures
• 24 Hr. Acq Log
• Orion Status
Present Total Consumption (not current total consumption, but rather last 
RF communication total consumption, usually < 1 hr. old)
Leak Detect (tripped by water meter, will reset on its own, or can be 
manually reset in the field; see the meter manufacturer documentation for 
trip and reset conditions)
Tamper Detect (must be field reset at water meter)
If there is a problem, the applicable error code is displayed. 
DRAFT