RadioFrame Networks Inc DH2 사용자 설명서

다운로드
페이지 164
RadioFrame System 
Equipment Commissioning 
RFN_3.1 Beta
  
101 
 
Cell Reselection (Mobile #) 
 
 
1  
 
 
2  
 
 
3  
 
 
5.6.1.5 
Interconnect Connection Stability and SQE Performance 
A single link for 3:1 Interconnect will be maintained for 30 minutes each. The 
following table presents the data to be collected for each selected link. The iDEN 
Field Test Application (IFTA) shall be used in “Single Cell” mode to observe the 
SQE performance and plotted over time. 
Table 7 
Interconnect Connection Stability 
Interconnect #1 
Carrier # 
RSSI (dBm) 
SQE (dB) 
Sector 
Duration (min) 
  
 
 
 
30 
Interconnect #2 
 
 
 
 
 
  
 
 
 
30 
Interconnect #3 
 
 
 
 
 
 
 
 
 
 
 
5.6.1.6 
Dispatch Connection Stability 
To verify Dispatch connection stability, a Dispatch (private or group) call will be 
maintained for several minutes. The following table presents the data to be 
collected for each dispatch call. 
Table 8 
Dispatch Connection Stability 
Dispatch #1 
Carrier # 
RSSI (dB) 
SQE (dB) 
Sector 
Quality 
(1-5) 
Duration 
(min) 
  
 
 
 
 
Dispatch #2 
 
 
 
 
 
 
  
 
 
 
 
Dispatch #3 
 
 
 
 
 
 
  
 
 
 
 
5.6.1.7 
Idle SQE Testing and Validation 
To validate SQE performance, the following test shall be conducted: 
1  Control Channel SQE: